Omron G2R-2-SNI 24 VAC PCB Mount Relay 24Vac 2 CO, DPDT G2R-2-SNI 24 VAC データシート

製品コード
G2R-2-SNI 24 VAC
ページ / 29
5
G2R
G2R
PCB/Fully sealed Relays
Note:
P level: 
l
60
 = 0.1 x 10
–6
/operation
Latching Relays
Note:
P level: 
l
60
 = 0.1 x 10
-6
/operation
Characteristics
Standard Relays
Note:
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Item
General-purpose (single contact)
Bifurcated contact
Number of poles
1 pole
2 poles
1 pole
Load
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Rated load
8 A at 250 VAC;
8 A at 30 VDC
6 A at 250 VAC; 
4 A at 30 VDC
4 A at 250 VAC;
4 A at 30 VDC
1.5 A at 250 VAC;
2.5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 
3 A at 30 VDC
Rated carry current
8 A
4 A
5 A
Max. switching voltage 380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current 8 A
4 A
5 A
Max. switching power
2,000 VA, 
240 W
1,500 VA, 
120 W
1,000 VA, 
120 W
375 VA, 
75 W
1,250 VA, 
150 W
500 VA, 
90 W
Failure rate 
(reference value)
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
Number of poles
1 pole
2 poles
Load
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Rated load
5 A at 250 VAC;
5 A at 30 VDC
3.5 A at 250 VAC;
2.5 A at 30 VDC
3 A at 250 VAC;
3 A at 30 VDC
1.5 A at 250 VAC;
2 A at 30 VDC
Rated carry current
5 A
3 A
Max. switching voltage 380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current 5 A
3 A
Max. switching power
1,250 VA, 150 W
875 VA, 75 W
750 VA, 90 W
375 VA, 60 W
Failure rate 
(reference value)
100 mA at 5 VDC
10 mA at 5 VDC
Item
1 pole
2 poles
Contact resistance
30 m
W
 max. (high-capacity type: 100 m
W
 max.)
50 m
W
 max.
Operate (set) time
15 ms max.
Release (reset) time
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Max. operating frequency
Mechanical: 18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
W
 min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and 
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts 
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and 
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts 
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts 
of same polarity
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: 200 m/s
2
 when energized; 100m/s
2
 when no energized
Endurance
Mechanical: AC coil: 10,000,000 operations min.; 
DC coil:
20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature
Operating: 
-
40
°
C to 70
°
C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 17 g (plug-in terminal: approx. 20 g)