UK 
9.6 Event 
memory 
The alarm system stores the last 250 events. To read the 
alarm memory:
 
 
Enter a valid user code. 
 
 
The control unit shows: 
 
 
 
 
 
Press: 
5
 
 
The LCD display shows the latest events first.
 
 
You can page forwards and backwards in the event 
memory. Press key 1 to page forwards and key 3 to page 
backwards.
 
 
Press 
 to switch between the event and the date.
 
 
Press 
 to exit the event memory.
 
 
The event memory cannot be deleted by the programmer 
or the user.
 
 
Entries in the event memory and their meaning: 
 
Entry
 
Meaning
 
Power fault
 
Failure of 230V AC power supply
 
Power OK
 
230V AC power supply restored
 
Alarm 
cancellation
 
Alarm aborted manually by user
 
AUX DC fault
 
12V DC power supply failed or AUX 
fuse defect
 
AUX DC fault 
OK
 
12V DC power supply restored
 
Bad Checksum
 
Error in alarm centre memory
 
Battery fault
 
Failure of battery charger or battery 
fuse defect
 
Battery fault OK
 
Battery charger restored
 
Break-in zone 
nn alarm
 
Zone nn has triggered a burglar 
alarm
 
Break-in Zone 
Zone nn OK
 
nn OK
 
Factory settings 
loaded
 
Factory settings restored
 
EEPROM fault
 
Memory error in the alarm centre
 
Fire zone nn 
alarm
 
Zone nn has triggered a fire alarm
 
Fire zone nn 
reset
 
Zone nn reset
 
Fire zone nn re-
connected
 
Zone nn re-connected
 
BDTnn code 
lock
 
A user has tried too often to enter 
code in the control unit
 
BDTnn fault
 
Control unit nn failed
 
BDTnn 
connected
 
Control unit nn reconnected
 
BDTnn Sabo
 
Control unit has triggered a tamper 
alarm
 
BDTnn Sabo OK Control unit nn tamper reset
 
BDTnn FE 
Alarm
 
Fire alarm triggered at control unit nn
BDTnn MN 
Alarm
 
Medical emergency alarm triggered 
at control unit nn
 
SSL active ZN 
nn
 
Alarm centre activated via key switch 
of zone nn
 
Entry
 
Meaning
 
SSL de-active 
ZN nn
 
Alarm centre deactivated via key 
switch of zone nn
 
SBox ZN nn 
closed
 
Zone nn with key box property closed
SBox ZN nn 
open
 
Zone nn with key box property 
opened
 
Sabo central 
alarm
 
The lid contact of the alarm centre 
was triggered
 
Sabo central 
alarm OK
 
The lid contact of the alarm centre is 
closed again
 
Battery fault
 
Fault in battery power supply
 
Battery fault OK
 
Fault in battery power supply 
remedied
 
BDTnn ÜF 
Alarm
 
BDT nn has triggered a panic alarm
 
Panic ZN nn 
alarm
 
Zone nn has triggered a panic alarm
 
Panic ZN nn 
reset
 
Panic alarm of zone nn reset
 
Aktiv fehlg. ZN 
nn
 
The alarm centre could not be 
activated since ZN nn was triggered