Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 データシート

製品コード
6ED1057-3BA00-0AA8
ページ / 378
 
Reference material 
 
5.3 Special functions 
LOGO!Soft Comfort Online Help 
Operating Instructions, 06/2014 
225
 
●  On-delay: Ta 
●  Off-delay: Ta 
●  On-/off-delay: Ta 
●  Retentive on-delay: Ta 
●  Wiping relay(pulse output): Ta 
●  Edge triggered wiping relay: Ta 
●  Asynchronous pulse generator: Ta 
●  Stairway light switch: Ta 
●  Multiple function switch: Ta 
●  Stopwatch: AQ 
●  Analog filter: AQ 
●  Average value: AQ 
●  Max/Min: AQ 
●  Threshold trigger: Fre 
You select the required function by the block number. 
Timing diagram 
 
Description of the function 
The input signal Trg = 1 sets the output Q to 1. The signal also triggers the time Ta, while the 
output remains set. 
When Ta reaches the value defined at T (Ta=T), the output Q resets to 0 state (pulse 
output). 
If the signal at input Trg changes from 1 to 0 before this time has expired, the output 
immediately resets from 1 to 0. 
Special functions (Page 212)  
5.3.1.6 
Edge triggered wiping relay