Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 データシート

製品コード
6ED1057-3BA00-0AA8
ページ / 378
 
Reference material 
 
5.3 Special functions 
LOGO!Soft Comfort Online Help 
Operating Instructions, 06/2014 
267
 
Parameter p (number of decimals) 
Parameter p applies only to the display of Aen, Ax, Threshold 1 and Threshold 2 values in a 
message text. 
Timing diagram 
 
Description of the function 
A 0 to 1 transition at input En saves the value of the signal at the analog input Ax. This saved 
process variable is referred to as "Aen". 
Both the analog actual values Ax and Aen are multiplied by the value at parameter A (gain), 
and parameter B (offset) is then added to the product, as follows:  
(Ax * gain) + offset = Actual value Aen, when input En changes from 0 to 1, or 
(Ax * gain) + offset = Actual value Ax. 
Output Q is set when the signal at input En = 1 and if the actual value at input Ax is out of 
range of Aen + Threshold 1 / Aen - Threshold 2. 
Output Q is reset, when the actual value at input Ax lies within the range of Aen + Threshold 
1 / Aen - Threshold 2, or when the signal at input En changes to lo. 
Particular characteristics to be noted when configuring 
Refer to the help on analog block parameters in the Analog value processing (Page 286)