Intel R2000BB4GS9 データシート
Intel
®
Server System R2000BB Product Family TPS
Revision 2.0
29
Table 19. System Fan Connector Pin-out
SYS_FAN 1
SYS_FAN 2
SYS_FAN 3
Signal Description
Pin#
Signal Description
Pin#
Signal Description
Pin#
FAN_TACH1_IN
1
FAN_TACH3_IN
1
FAN_TACH5_IN
1
FAN_IBMC_PWM0_R_BUF
2
FAN_IBMC_PWM1_R_BUF
2
FAN_IBMC_PWM2_R_BUF
2
P12V_FAN
3
P12V_FAN
3
P12V_FAN
3
P12V_FAN
4
P12V_FAN
4
P12V_FAN
4
FAN_TACH0_IN
5
FAN_TACH2_IN
5
FAN_TACH4_IN
5
GROUND
6
GROUND
6
GROUND
6
GROUND
7
GROUND
7
GROUND
7
FAN_SYS0_PRSNT_N
8
FAN_SYS1_PRSNT_N
8
FAN_SYS2_PRSNT_N
8
LED_FAN_FAULT0_R
9
LED_FAN_FAULT1_R
9
LED_FAN_FAULT2_R
9
LED_FAN0
10
LED_FAN1
10
LED_FAN2
10
SYS_FAN 4
SYS_FAN 5 (Not used)
SYS_Fan 6
Signal Description
Pin#
Signal Description
Pin#
Signal Description
Pin#
FAN_TACH7_IN
1
FAN_TACH9_IN
1
FAN_TACH11_IN
1
FAN_IBMC_PWM3_R_BUF
2
FAN_IBMC_PWM4_R_BUF
2
FAN_IBMC_PWM5_R_BUF
2
P12V_FAN
3
P12V_FAN
3
P12V_FAN
3
P12V_FAN
4
P12V_FAN
4
P12V_FAN
4
FAN_TACH6_IN
5
FAN_TACH8_IN
5
FAN_TACH10_IN
5
GROUND
6
GROUND
6
GROUND
6
GROUND
7
GROUND
7
GROUND
7
FAN_SYS3_PRSNT_N
8
FAN_SYS4_PRSNT_N
8
FAN_SYS5_PRSNT_N
8
LED_FAN_FAULT3_R
9
LED_FAN_FAULT4_R
9
LED_FAN_FAULT5_R
9
LED_FAN3
10
LED_FAN4
10
LED_FAN5
10
4.4 Power Supply Module Fan
Each installed power supply module includes one embedded (non-removable) 40-mm fan. It is responsible for
airflow through the power supply module. This fan is managed by the fan control system. Should this fan fail,
the power supply will continue to operate until its internal temperature reaches an upper critical limit. The
power supply will be protected against over temperature conditions caused by loss of fan cooling or excessive
ambient temperature. In an over-temperature protection condition, the power supply module will shut down.
airflow through the power supply module. This fan is managed by the fan control system. Should this fan fail,
the power supply will continue to operate until its internal temperature reaches an upper critical limit. The
power supply will be protected against over temperature conditions caused by loss of fan cooling or excessive
ambient temperature. In an over-temperature protection condition, the power supply module will shut down.
4.5 FRUSDR Utility
The purpose of the embedded platform management and fan control systems is to monitor and control various
system features, and to maintain an efficient operating environment. Platform management is also used to
communicate system health to supported platform management software and support mechanisms. The
FRUSDR utility is used to program the server board with platform specific environmental limits, configuration
data, and the appropriate sensor data records (SDRs), for use by these management features.
The FRUSDR utility must be run as part of the initial platform integration process before it is deployed into a
live operating environment. It must be run with the system fully configured and each time the system
configuration changes.
The FRUSDR utility for the given server platform can be run as part of the Intel
system features, and to maintain an efficient operating environment. Platform management is also used to
communicate system health to supported platform management software and support mechanisms. The
FRUSDR utility is used to program the server board with platform specific environmental limits, configuration
data, and the appropriate sensor data records (SDRs), for use by these management features.
The FRUSDR utility must be run as part of the initial platform integration process before it is deployed into a
live operating environment. It must be run with the system fully configured and each time the system
configuration changes.
The FRUSDR utility for the given server platform can be run as part of the Intel
®
Server Deployment Toolkit
and Management DVD that ships with each Intel server, or can be downloaded from http://
http://downloadcenter.intel.com.
http://downloadcenter.intel.com.
Note: The embedded platform management system may not operate as expected if the platform is not updated
with accurate system configuration data. The FRUSDR utility must be run with the system fully configured and
each time the system configuration changes for accurate system monitoring and event reporting.
with accurate system configuration data. The FRUSDR utility must be run with the system fully configured and
each time the system configuration changes for accurate system monitoring and event reporting.