Intel R2000BB4GS9 データシート

ページ / 89
Intel
®
 Server System R2000BB Product Family TPS 
 
Revision 2.0 
 
 
 
29 
Table 19. System Fan Connector Pin-out 
SYS_FAN 1 
SYS_FAN 2 
SYS_FAN 3 
Signal Description 
Pin# 
Signal Description 
Pin# 
Signal Description 
Pin# 
FAN_TACH1_IN 
FAN_TACH3_IN 
FAN_TACH5_IN 
FAN_IBMC_PWM0_R_BUF 
FAN_IBMC_PWM1_R_BUF 
FAN_IBMC_PWM2_R_BUF 
P12V_FAN 
P12V_FAN 
P12V_FAN 
P12V_FAN 
P12V_FAN 
P12V_FAN 
FAN_TACH0_IN 
FAN_TACH2_IN 
FAN_TACH4_IN 
GROUND 
GROUND 
GROUND 
GROUND 
GROUND 
GROUND 
FAN_SYS0_PRSNT_N 
FAN_SYS1_PRSNT_N 
FAN_SYS2_PRSNT_N 
LED_FAN_FAULT0_R 
LED_FAN_FAULT1_R 
LED_FAN_FAULT2_R 
LED_FAN0 
10 
LED_FAN1 
10 
LED_FAN2 
10 
SYS_FAN 4 
SYS_FAN 5 (Not used) 
SYS_Fan 6 
Signal Description 
Pin# 
Signal Description 
Pin# 
Signal Description 
Pin# 
FAN_TACH7_IN 
FAN_TACH9_IN 
FAN_TACH11_IN 
FAN_IBMC_PWM3_R_BUF 
FAN_IBMC_PWM4_R_BUF 
FAN_IBMC_PWM5_R_BUF 
P12V_FAN 
P12V_FAN 
P12V_FAN 
P12V_FAN 
P12V_FAN 
P12V_FAN 
FAN_TACH6_IN 
FAN_TACH8_IN 
FAN_TACH10_IN 
GROUND 
GROUND 
GROUND 
GROUND 
GROUND 
GROUND 
FAN_SYS3_PRSNT_N 
FAN_SYS4_PRSNT_N 
FAN_SYS5_PRSNT_N 
LED_FAN_FAULT3_R 
LED_FAN_FAULT4_R 
LED_FAN_FAULT5_R 
LED_FAN3 
10 
LED_FAN4 
10 
LED_FAN5 
10 
 
4.4  Power Supply Module Fan 
Each installed power supply module includes one embedded (non-removable) 40-mm fan. It is responsible for 
airflow through the power supply module. This fan is managed by the fan control system.  Should this fan fail, 
the power supply will continue to operate until its internal temperature reaches an upper critical limit.  The 
power supply will be protected against over temperature conditions caused by loss of fan cooling or excessive 
ambient temperature. In an over-temperature protection condition, the power supply module will shut down.  
4.5  FRUSDR Utility 
The purpose of the embedded platform management and fan control systems is to monitor and control various 
system features, and to maintain an efficient operating environment.  Platform management is also used to 
communicate system health to supported platform management software and support mechanisms. The 
FRUSDR utility is used to program the server board with platform specific environmental limits, configuration 
data, and the appropriate sensor data records (SDRs), for use by these management features. 
 
The FRUSDR utility must be run as part of the initial platform integration process before it is deployed into a 
live operating environment.  It must be run with the system fully configured and each time the system 
configuration changes. 
 
The FRUSDR utility for the given server platform can be run as part of the Intel
®
 Server Deployment Toolkit 
and Management DVD that ships with each Intel server, or can be downloaded from http:// 
http://downloadcenter.intel.com. 
Note: The embedded platform management system may not operate as expected if the platform is not updated 
with accurate system configuration data. The FRUSDR utility must be run with the system fully configured and 
each time the system configuration changes for accurate system monitoring and event reporting.