Advanced Operation
ALarm
4.  Click APPLY. Click OK in the confirmation window.
Alarm Inputs:
Alarm inputs are devices or switches that activate when a door, window, cabinet etc. is opened or accessed. For example, 
you might want to only have the camera record when someone opens a tool cabinet or when a door opens vs. recording when 
motion occurs around those areas. There may be people moving by those areas frequently but you are only concerned about 
when those areas are accessed. This saves hard drive space and makes it easier to find an event that was recorded to the 
hard drive. 
To configure alarm inputs for devices without their own voltage you 
will use the +12V input supplied on the alarm block. See Alarm Inputs 
Configuration diagram at the right.
Note: If Alarm Input Device has its own power supply make sure:
1.  Voltage rating is between 6V and 12V. Do not use the +12V 
connection on the Alarm Block.
2.  Ground must be connected to GND in Alarm Block for device to 
operate properly
When an alarm is triggered, in the Live View Screen you will see a 
red
I】
in the Channel with an alarm input warning. You may also 
see a
R】
if you set up the channel to record when an alarm is 
triggered.
Alarm Ouput:
Alarm output is used to activate an external device such as a 
horn or light after an alarm is triggered. To do this the DVR uses a 
dry contact normally open relay. This DVR has two sets of alarm 
outputs: COM1/NO1 and COM2/NO2. To configure alarm outputs, 
connect the external device to the NO (Normally Open) and COM 
(Common) connections on the alarm block as required by the device. See 
table for Alarm Block Voltage. The maximum contact rating is 3A 24VDC. Note: 
ALARM MANAGE settings work the same on both outputs. Alarm inputs 1 and 
2 activate alarm output COM1/NO1. Alarm inputs 3 and 4 activate alarm output 
COM2/NO2.
E-mail Setup:
The system can send an e-mail notification with a JPEG snapshot for triggered 
events on the system. Please consult your e-mail provider for information to enter 
in this screen. To setup e-mail notification:
1.  Under EMAIL, select ON.
2.  Under SSL, select OFF. NOTE: SSL deals with encryption. Only advanced 
users should enable this option.
3.  Under SMTP PORT, enter the SMTP port of your e-mail server.
4.  Under SMTP, enter the SMTP address of your e-mail server. For example, 
smtp.gmail.com
5.  Under SEND EMAIL, enter the sender e-mail address.
6.  Under SEND PW, enter the password of your e-mail server.
7.  Under RECV EMAIL, enter the e-mail address that will receive the e-mail 
notification.
8.  INTERVAL: Set from 3 -240 minutes
9.  SET EMAIL CC: Add up to six Carbon Copy e-mail addresses.
10.  Click APPLY. Click OK in the REMARK window.
E-mail Tip
Depending upon your settings, the system can generate a lot 
of e-mail alerts. For that reason, we recommend setting up a 
dedicated e-mail address specifically for the Security System 
alert notices. Also to better manage your alerts, you will want 
the alert e-mails to go to a different account than the one sending them.
From NO or NC depending on 
setup  selected to alarm 
inputs 1 through 4
COM
NO
NC
Example Device: 
Door Sensor
Use +12V from 
Alarm Block
Alarm Inputs Configuration
(for devices without voltage)
Note: If Alarm Input Device has its own power supply make sure:
1) Voltage rating is between 6V and 24V. The +12V input is not used on Alarm Block.
2) Ground must be connected to GND in Alarm Block for device to operate properly
485A
-1
485B
-1
GND
GND
NO1
COM2
ALM   IN
1
4
3
2
GND
+ 12V
GND
485A
-2
485B
-2
COM1
NO2 GND
E-mail Setup Screen
Alarm Block Voltage
Max Switching Voltage
up to 24VDC
Max Switching Current
up to3A
E-mail Carbon Copy Setup