WARNING:
 To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: 
Observe all governing codes and ordinances.
 
Dryer vent must not be connected into any gas vent,  
chimney, wall, ceiling, attic, crawlspace, or a concealed space  
of a building. 
If using an existing vent system
 
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
 
Replace any plastic or metal foil vent with rigid heavy metal 
vent or flexible metal vent.
 
Review Vent System Chart. Modify existing vent system if 
necessary to achieve the best drying performance. Only rigid 
or flexible metal vent shall be used for exhausting.
If this is a new vent system
Vent material
 
Use a heavy metal vent. Do not use plastic or metal foil vent.
 
4" (102 mm) heavy metal vent and clamps must be used.
Rigid metal vent
 
Recommended for best drying performance and to avoid 
crushing and kinking.
Flexible metal vent
 
Must be fully extended and supported when the dryer is in it’s 
final location. 
 
Remove excess to avoid sagging and kinking that may result 
in reduced airflow and poor performance.
 
Do not install flexible metal vent in enclosed walls, ceilings, or 
floors.
Venting Requirements
4" (102 mm) heavy metal exhaust vent
Elbows:
Plan installation to use the fewest number of elbows and turns.
Clamps:
 
Use clamps to seal all joints.
 
Exhaust vent must not be connected or secured with screws 
or other fastening devices which extend into the interior of the 
vent and catch lint. Do not use duct tape.
Exhaust
Recommended hood styles. 
Acceptable hood style.
   
4"
(102 mm)
2
½"
(64 mm)
     
4"
(102 mm)
      
4"
(102 mm)
B
A
C
A.  Louvered hood style
B.  Box hood style
C.  Angled hood style is acceptable
 
An exhaust hood should cap the vent to keep rodents and 
insects from entering the home or business.
 
Exhaust hood must be at least 12" (305 mm) from the ground 
or any object that may be in the path of the exhaust (such as 
flowers, rocks, or bushes).
 
Do not use an exhaust hood with a magnetic latch.
 
A four-inch outlet hood is preferred. However, a 2
1
2
" (64 mm) 
outlet exhaust hood may be used. A 2
1
2
" (64 mm) outlet 
creates greater back pressure than other hood types. For 
permanent installation, a stationary vent system is required.
Plan Vent System
Determine vent path:
 
Vent outlet is located at the center of the bottom dryer back. 
 
The vent can be routed up, down, left, right, behind the dryer, 
or straight out the back of the dryer.
 
When using elbows or making turns, allow as much room as 
possible. 
 
Bend vent gradually to avoid kinking.
Good
Better