Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 199 of 238
02.04.2002
8.25  AT^SNFS  Select audio hardware set
Test command
AT^SNFS=?
Response
^SNFS: (list of supported
 <audMode>s) OK
Parameter
See write command
Read command
AT^SNFS?
Response
^SNFS: <audMode> OK
Parameter
See write command
Write command
AT^SNFS=
<audMode>
The write command serves to set the audio mode required for the connected
equipment. Please note that the selected mode is not saved to the non-volatile
store and needs to be restored manually, if the GSM engine was powered down.
Response
OK
If error is related to ME functionality:
+ CME ERROR: <error>
Parameters
<audMode> 1
Audio mode 1: Standard mode optimized for the default handset,
that can be connected to the analog interface 1 (see your
"Hardware Interface Description" for information on this hand-
set.) To adjust the volume use the knob of the default handset.
This handset can be used in audio mode 4 with user defined pa-
rameters.
Note: The default parameters are determined for type approval
and are not adjustable with AT commands.
2
Audio mode 2: Customer specific mode for a basic handsfree
device (Siemens Car Kit Portable) connected to the analog in-
terface 2. Audio parameters can be adjusted with AT commands
3
Audio mode 3: Customer specific mode for a mono-headset that
connects to the analog interface 2. Audio parameters can be
adjusted with AT commands.
4
Audio mode 4: Customer specific mode for a user handset that
connects to the analog interface 1. Audio parameters can be
adjusted with AT commands.
5
Audio mode 5: Customer specific mode intended for the analog
interface 1. Audio parameters can be adjusted with AT com-
mands.
6
Audio mode 6: Customer specific mode intended for the analog
interface 2. Audio parameters can be adjusted with AT com-
mands.
Reference
Siemens
Note