Toshiba VF-AS1 ユーザーズマニュアル
!
!
!
E
6
5
8
1
3
0
1
!
11
K
-2
2. Basic parameter [2/4]
Sensorless vector/vector with sensor (
Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f
Reference
Speed
control
Torque
control
control
RV
0015
V/f control mode selection
0:Constant torque characteristics
1:Voltage decrease curve
2:Automatic torque boost
3:Sensorless vector control 1 (speed)
4:Sensorless vector control 2 (speed/torque)
5:V/f 5-point setting
6:PM control
7:PG feedback control
8:PG feedback vector control
1:Voltage decrease curve
2:Automatic torque boost
3:Sensorless vector control 1 (speed)
4:Sensorless vector control 2 (speed/torque)
5:V/f 5-point setting
6:PM control
7:PG feedback control
8:PG feedback vector control
1/1
0
Disabled
-/-
-/-
-/-
Ɣ/-
Ɣ/-
Ɣ/-
-/-
-/-
-/-
-/
Ɣ
-/
Ɣ
-/-
-/-
-/-
-/-
-/-
-/-
-/-
Ɣ/-
-/-
-/-
-/-
-/-
-/-
-/
Ɣ
-
-
-
-
-
-
-
-
-
-
-
Ɣ
-
-
-
Ɣ
Ɣ
-
-
-
-
-
Ɣ
-
-
-
-
-
5. 6
XD
0016
Manual torque boost 1
0.0~30.0%
0.1/0.1
*1
Enabled
-
-
Ɣ
Ɣ
5. 7
XN
0014
Base frequency 1
25.0~500
ҢҢҠҢ Hz
0.1/0.01
*3
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
5. 8
XNX
0409
Base frequency voltage 1
200V class:50~330V
400V class:50~660V
400V class:50~660V
1/0.1
*1
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
5. 8
HJ
0011
Maximum frequency
30.0~500.0Hz
0.1/0.01
80.0
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
5. 9
WN
0012
Upper limit frequency
0.0~HJ Hz
0.1/0.01
*3
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 10
NN
0013
Lower limit frequency
0.0~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 10
CEE
0009
Acceleration time 1
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 2
FGE
0010
Deceleration time 1
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 2
CXH
0213
RR/S4 input point 2
frequency
frequency
0.0~HJ Hz
0.1/0.01
*3
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 11
CKH
0204
VI/II input point 2 frequency 0.0~HJ Hz
0.1/0.01
*3
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 11
UT
0018
Preset speed operation
frequency 1
frequency 1
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
UT
0019
Preset speed operation
frequency 2
frequency 2
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
UT
0020
Preset speed operation
frequency 3
frequency 3
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
UT
0021
Preset speed operation
frequency 4
frequency 4
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
UT
0022
Preset speed operation
frequency 5
frequency 5
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
UT
0023
Preset speed operation
frequency 6
frequency 6
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
UT
0024
Preset speed operation
frequency 7
frequency 7
NN~WN Hz
0.1/0.01
0.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
5. 12
HT
0008
Forward run/reverse run
selection (operation panel
operation)
selection (operation panel
operation)
0:Forward run
1:Reverse run
2:Forward run (Forward/reverse switchable on operation
1:Reverse run
2:Forward run (Forward/reverse switchable on operation
panel)
3:Reverse run (Forward/reverse switchable on
operation panel)
1/1
0
Enabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
5. 13
*1: Default values vary depending on the capacity. See the table of K-48.
*2: Changing the parameter VR enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
*3: Inverter with a model number ending with -WN, HN: 60.0 -WP: 50.0
*2: Changing the parameter VR enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
*3: Inverter with a model number ending with -WN, HN: 60.0 -WP: 50.0