Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
!
!
!
E
6
5
8
1
3
0
1
!
11
K
-4
2. Basic parameter [4/4] 
Sensorless vector/vector with sensor (
Ɣ:Effective, -:Ineffective) 
Title 
Communi
cation 
No. 
Function 
Adjustment range 
Minimum 
setting unit 
(Panel/Communi
cation)
Default 
setting
Write during 
running 
Vector control
PM 
control
V/f 
Reference
Speed 
control
Torque 
control
RD
0304 
Dynamic braking 
selection 
Setting
Braking 
function
ST-off 
Overload detect
1/1 
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
5. 19 

Disabled
ʊ
ʊ

Enabled (It is 
effective in trip 
condition.) The 
state of QNT
trip is excluded.
Enabled
protect

not protect

Disabled
protect

not protect

Enabled (It isn't 
effective in trip 
condition )
Enabled
protect

not protect

Disabled
protect

not protect
RDT
0308
Dynamic braking resistance 0.5~1000
Ÿ
0.1/0.1
*1
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
5. 19
RDER
0309 
Dynamic braking resistor 
continuous capacity 
0.01~600.0kW 
0.01/0.01
*1 
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
5. 19 
V[R
0007 
Factory default setting 
0: - 
1:50 Hz default setting 
2:60 Hz default setting 
3:Factory default setting 
4:Trip clear 
5:Cumulative operation time cleared 
6:Initialization of type information 
7:Save user-defined parameters 
8:Reset of user-defined parameters 
9:Cumulative fan operation time record clear 
10:Acceleration/deceleration time setting 0.01 
sec.~600.0 sec.   
11:Acceleration/deceleration time setting 0.1 
sec.~6000sec.   
1/1 
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
5. 20 
RUGN
0050 
Registered parameter 
display selection 
0:Standard setting mode at time of activation of motor
1:Quick mode at time of activation of motor 
2:Quick mode only 
1/1 
Enabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
5. 22 
H
H
Extended parameters 
Set detailed parameters shown in the following pages.   
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
ITW
-
Automatic edit function
-
-
-
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
4. 2
*1: Default values vary depending on the capacity. Ÿ See the table of K-48.