Oracom PROFI MX160 ユーザーズマニュアル

ページ / 28
Note
For configuration of the menu using program Setr see „MORSE firmware documentation
1
A supply voltage can be applied to the board via the MR400 supply connector. In this case simply
connect a wire with a positive voltage. When supplying from an external power source both leads need
to be connected.
Tab. 3.6: M-BUS module parameters
300–9600 bps
Communication rate
1–5
Number of SLAVE meters
yes
Galvanic separation
yes
Protection and indication of a s/c on the bus
external, 11–14 V/100 mA
Power supply
100 nF/9600 bps, 1000 nF/300 bps
Max. capacity of lead
Tip
A supply voltage can be applied to the board via the MR400 supply connector. In this case
simply connect a wire with a positive voltage. When supplying from an external power source
both leads need to be connected.
+
+
+
PWR
M-BUS
Fig. 3.8: Description of S-BUS module connectors
Module connectors
supply connector – terminals
M-BUS – terminals
Key to LED colours
Tab. 3.7: Key to M-BUS module LEDs
Tx – transmitting data to M-BUS
red
Rx – receiving data from M-BUS
orange
OVL – overloading or s/c on M-BUS
yellow
3.6. GPS Module
A GPS module can be positioned in the first or second slot of optional modules, see section Section 3.11,
“View of Radio Modem”. 
(For MG100 only in the first slot.) The second slot is recommended because
when using slot 1 you first need to disconnect it in the modem´s service mode, see section Section 3.10,
“Service Connector”. 
You can find further detailed information on the module manufacturer’s web
pages
.
GPS module connectors
antenna connector – SMA female – marked ANT
1
https://www.racom.eu/cz/support/firmware/mr400/index.html
2
http://www.u-blox.com/products/modules.html
15
© RACOM s.r.o. – Wideband modems – PROFI MX160
Connectors