data connector – DSUB9 (Canon) – marked NMEA
Antenna connector for an active antenna – the antenna supply to the antenna connector is short-circuit
proof
Tab. 3.8: Connection of data cable
RS232 signal
DSUB9F
pin
+3,3 V through 10 k resistor
1
data NMEA output
2
see Note
3
input ALARM 0 (from sw v. 8.05)
4
GND
5
output 1 PPS (pulse per second)
6
input ALARM 1
7
see Note
8
unwired
9
Note
Inputs ALARM 0, 1 are passive, a positive 3-15 V voltage should be applied for accepting
functions. For the contact activacion can be connect the positive potential from pin No.
1.
Pin No. 3 becomes the input for configuration data, if we connect pin No. 8 to GND.
The behaviour of time pulses at pin No. 6 (default)
+6 V
1 s
100 ms
-6 V
900 ms
Meaning of LED colours
Tab. 3.9: Meaning of GPS module LEDs
TP – Time Pulse
red
St – Status (in progress)
green
The GPS is providing the correct data if the red LED is flashing to the rhythm of time pulses (typically
1 s).