Installation 
3-12 
P/N 8040540
C
HELIX  TECHNOLOGY  CORPORATION
-
TI
CRYOGENICS
Power Cable Connections
1. Connect the On-Board Splitter Box power cable between the 
CRYOPUMP ELECTRICAL OUTLET on the rear panel of the 
Compressor and the On-Board Splitter Box power connector as 
shown in Figure 3-6.
2. Connect the On-Board Cryopump or Waterpump power cables to 
the CRYOPUMP 1, 2, or 3 connectors on the On-Board Splitter 
Box and the respective cryopumps as shown in Figure 3-6.
NOTE: Your installation (number of pumps per compressor) will  vary 
based upon the On-Board Cryopump models used.  Refer to Appendix A to 
consult your local CTI-CRYOGENICS Customer Support Center for 
information on specific compressor/pump applications.
NOTE: The On-Board Splitter Box can be installed at the process tool  
containing the pumps as shown in Figure 3-6, or on the rear of the 
Compressor as shown in Figure 3-7.  CTI-CRYOGENICS recommends that 
the On-Board Splitter box be installed near the process tool to reduce cable 
requirements.
Figure 3-6: Recommended Multiple On-Board Cryopump or Waterpump Installation 
(Splitter Box  located at Process Tool)
HELIUM SUPPLY
HELIUM RETURN
WATER
POWER
ON-BOARD POWER CABLE
REMOTE
ON-BOARD SPLITTER
BOX