9600 Compressor Installation, Operation, and Maintenance
P/N 8040540
3-13
C
HELIX  TECHNOLOGY  CORPORATION
-
TI
CRYOGENICS
Figure 3-7: Alternative Multiple On-Board Cryopump or Waterpump Installation           
(Splitter Box located at Compressor)
Multiple Cryo-Torr Cryopump Connections
CAUTION
Make sure the Compressor power is OFF before making any   
connections to the rear panel.
Helium Line Connections
CAUTION
The use of several compressors on a single manifold feeding a common 
supply header and a common return header requires special 
precautions. Contact CTI-CRYOGENICS for a review of the intended 
installation and for specific technical instructions. 
The use of a 9600 compressor on a manifold with other                      
CTI-CRYOGENICS compressor models requires a reduction of the 
helium charge pressure to 200 - 210 psig charge pressure to avoid 
helium safety valves from inadvertently venting.  Refer to Section 4 - 
Operation
 and Section 5 - Maintenance for more information.
HELIUM SUPPLY
HELIUM RETURN
WATER
POWER
ON-BOARD POWER CABLES
REMOTE
ON-BOARD 
SPLITTER
BOX