Honeywell VCR DCP200 ユーザーズマニュアル

ページ / 184
DCP200 Profile Controller & Recorder - Product Manual
Page 36
Electrical Installation
51-52-25-150, Issue 1 – April 2009
Option Slot A Connections - RS485 Serial Communications Module
If option slot A is fitted with the RS485 serial communication module, connections are as 
illustrated. Carefully observe the polarity of the A (Rx/Tx +ve) and B (Rx/Tx -ve) connections.
Figure 34.
Option Slot A – RS485 Serial Communications Module
CAUTION:
External computing devices connected to the communications port should comply 
with the standard, UL 60950.
Option Slot B Connections
Option Slot B Connections – Digital Input B (Full Auxiliary Module)
If option slot B is fitted with the Full Auxiliary input module (see below), a secondary digital 
input is also provided. This may be connected to the voltage free contacts of a switch or 
relay, or to a TTL compatible voltage.
Figure 35.
Option Slot B – Digital Input B Connections
Option Slot B Connections – Full Auxiliary Input B Module
If option slot B is fitted with full auxiliary input feature, input connections are as shown.
Figure 36.
Option Slot B – Full Auxiliary Input Connections
9
8
_
+
7
6
5
(or Pot Low)
_
+
(or Pot Wiper)
(or Pot High)
RS485
A
B
16
17
18
COM