Table 6 - Troubleshooting Procedures
Problem
Possible Cause
Solution
1. Capacity display stays 
at 9999 even though 
there is water usage.
a. Total system capacity was 
calculated to be a value greater than 
9999.
a. As the water usage continues, the 
remaining capacity will drop below 
9999 and then other values will be 
shown.
2. Timer beeps when left 
arrow button is 
pressed.
a. Button is only active in the 
programming mode.
a. Refer to the Programming the Control 
section.
3. Timer does not 
respond to REGEN 
button.
a. Button is not active in the 
programming mode.
a. Refer to the Regeneration section.
4. Timer does not display 
time of day.
a. Transformer unplugged.
b. No electric power at outlet.
c. Defective transformer.
d. Defective circuit board.
a. Connect power.
b. Repair outlet or use working outlet.
c. Replace transformer.
d. Replace control.
5. Timer does not display 
correct time of day.
a. Outlet operated by a switch.
b. Power outages.
a. Use outlet not controlled by switch.
b. Reset Time of Day.
6. No water flow display 
when water is flowing 
(colon does not blink).
a. Bypass valve in bypass position.
b. Meter probe disconnected or not 
fully connected to meter housing.
c. Restricted meter turbine rotation 
due to foreign material in meter !
d. Defective meter probe.
e. Defective circuit board.
a. Shift bypass valve into service 
position.
b. Fully insert probe into meter housing.
c. Remove meter housing, free up turbine 
and flush with clean water. Turbine 
should spin freely. If not, refer to the 
Water Meter Maintenance section.
d. Replace control.
e. Replace control.
7. Control display is 
frozen at Regen Time 
Remaining.
a. Back to back regenerations were 
requested.
a. Refer to the Manual Regeneration 
section.
8. Control regenerates at 
the wrong time of day.
a. Power outages.
b. Time of day set incorrectly.
c. Time of regeneration set incorrectly.
a. Reset time of day to correct time of 
day.
b. Reset time of day to correct time of 
day.
c. Reset time of regeneration.
9. Timer stalled in 
regeneration cycle.
a. Motor not operating.
b. Motor runs backwards.
c. No electric power at outlet.
d. Incorrect voltage or frequency (Hz).
e. Broken gear.
f.
Defective switch.
g. Air leak in brine connections 
(pressure locked flapper).
h. Binding of camshaft.
i.
Water pressure greater than 
125 psi during regeneration.
j.
Defective circuit board.
a. Replace control.
b. Replace control.
c. Repair outlet or use working outlet.
d. Replace timer and/or transformer with 
one of correct voltage and frequency 
(Hz).
e. Replace control.
f.
Replace control.
g. Check all junction points and make 
appropriate corrections.
h. Remove foreign object obstruction 
from valve discs or camshaft.
i.
Install pressure regulator to reduce 
pressure.
j.
Replace control.