Water Boss Series 255 ユーザーズマニュアル

ページ / 28
27
Problem
Possible Cause
Solution
10. Continuous 
regeneration. 
Camshaft does not 
stop at the end of 
regeneration.
a. Broken projection on drive gear.
b. Defective switch.
a. Replace control.
b. Replace control.
11. Control does not 
regenerate 
automatically or when 
REGEN button is 
depressed.
a. Transformer unplugged.
b. No electric power at outlet.
c. Defective motor.
d. Broken gear.
e. Binding in gear train.
f.
Defective switch.
a. Connect power.
b. Repair outlet or use working outlet.
c. Replace control.
d. Replace control.
e. Replace control.
f.
Replace control.
12. Control does not 
regenerate 
automatically but does 
regenerate when 
REGEN button is 
depressed.
a. If water flow display is not operative, 
refer to item 5 in this table.
b. Incorrect hardness and capacity 
settings.
c. Defective circuit board.
a. Refer to item 5 in this table.
b. Set new control values. Refer to the 
Programming section.
c. Replace control.
13. Run out of soft water 
between 
regenerations.
a. Improper regeneration.
b. Fouled resin bed.
c. Incorrect salt setting.
d. Incorrect hardness or capacity 
settings.
e. Water hardness has increased.
f.
Restricted meter turbine rotation 
due to foreign material in meter 
housing !
g. Excessive water usage below 
1/5 gallon per minute.
a. Repeat regeneration making certain 
that correct salt dosage is used.
b. Use resin cleaner.
c. Set salt control to proper level. Refer to 
the Programming section in this 
manual.
d. Set to correct values. Refer to the 
Programming section of this manual.
e. Set to correct value. Refer to the 
Programming section in this manual.
f.
Remove meter housing, free up 
turbine, and flush with clean water. 
Turbine should spin freely; if not, 
replace meter.
g. Repair leaky plumbing and/or fixtures.
14. Control does not draw 
brine.
a. Low water pressure.
b. Restricted drain line.
c. Injector or injector screen plugged !
d. Injector defective !
e. Valve disc 2 and/or 3 not closed.
f.
Air check valve prematurely closed.
a. Increase water pressure.
b. Remove restriction.
c. Clean injector and screen. Refer to the 
Cleaning the Injector/Injector Screen 
section in this manual.
d. Replace injector and cap.
e. Manually operate valve stem to flush 
out foreign matter holding disc open. 
Replace if needed.
f.
Briefly put control into brine refill 
status. Refer to the Manual 
Regeneration section in this manual. 
Replace or repair air check valve if 
needed.
Table 6 - Troubleshooting Procedures