Problem
Possible Cause
Solution
15. Brine tank overflow.
a. Brine valve disc 1 held open.
b. Valve disc 2 not closed during brine 
draw, causing brine refill.
c. Air leak in brine line to air check.
d. Salt setting too high.
a. Manually operate valve stem to flush 
out foreign matter holding disc open.
b. Manually operate valve stem to flush 
out foreign matter holding disc open.
c. Check all connections in brine line for 
leaks.
d. Set in new values. Refer to 
Programming section in this manual.
16. System using more or 
less salt than salt 
setting.
a. Inaccurate setting.
b. Foreign matter in salt controller 
causing incorrect flow rate.
c. Defective circuit board.
a. Correct salt setting. Refer to the 
Programming section in this manual.
b. Manually position control to BRINE/
SLOW RINSE to clean controller.
c. Replace control.
17. Intermittent or irregular 
brine draw.
a. Low water pressure.
b. Defective injector !
a. Increase water pressure (20 psi at 
conditioner).
b. Replace both injector and injector cap.
18. No conditioned water 
after regeneration.
a. Unit did not regenerate.
b. No salt in brine tank.
c. Plugged injector !
d. Air check valve closed prematurely.
a. Check for power.
b. Add salt to brine tank.
c. Remove injector and flush it and 
injector screen.
d. Put control momentarily into REFILL to 
free air check. Replace or repair air 
check if needed. Refer to instructions.
19. Control backwashes at 
excessively low or high 
rate.
a. Incorrect backwash controller !
b. Foreign matter affecting controller 
operation !
a. Replace with correct size controller.
b. Remove and clean controller and ball.
20. Flowing or dripping 
water at drain line or 
brine line after 
regeneration.
a. Drain valve (5 or 6) or brine valve (1) 
held open by foreign matter.
b. Weak valve stem return spring on 
top plate.
c. Resin in valve.
a. Manually operate valve stem to flush 
out foreign matter holding disc open.
b. Replace spring.
c. Clean valve and backwash control.
21. Hard water leakage 
during service.
a. Improper regeneration.
b. Leaking of bypass valve !
c. O-ring around riser tube 
damaged !
a. Repeat regeneration making sure that 
the correct salt dosage is used.
b. Replace O-ring.
c. Replace O-ring.