3.2.6.  TERMINAL VOLTAGE:  
3.2.6.1.  Programmable, in accordance with the number of cells selected, at the 
equivalent of 1 VOLT/cell. 
3.2.6.2.  TOLERANCE: ±1% ±0.1 VOLT. 
3.2.6.3.  NOTE 1: Due to cable/connector losses the voltage registered by the 
Charger-Analyzer will be lower than the actual battery voltage (up to 
0.2V depending on current).  
3.2.6.4.  NOTE 2: Terminal voltage is ignored in the full discharge mode. 
3.2.7.  OVERHEAT PROTECTION:  
3.2.7.1.  Two thermistors measure the temperature of the bank of discharge 
transistors. 
3.2.7.2.  Operation is terminated if the transistors surface temperature exceeds 
90
o
C. 
3.2.8.  OVER/UNDER CURRENT PROTECTION:  
3.2.8.1.  A Monitor circuit continuously compares the actual discharge current 
with the programmed value 
3.2.8.2.  Operation is terminated if they differ by more than 1 AMP. 
3.2.8.3.  NOTE:  Undercurrent monitoring is disabled in the full discharge 
mode for battery voltages below 2.5V. 
3.2.9.  REVERSE POLARITY PROTECTION:  
3.2.9.1.  Operation of the unit is inhibited for reverse voltages greater than 0.5V 
3.2.10.  FUSING:  
3.2.10.1.  Aircraft type current limiter, ANN-80(fast). 
3.2.10.2.  NOTE:  The type of limiter and current rating are critical for proper 
protection of the discharge circuits. Failure to replace the discharge 
current limiter with the proper type/value may result in catastrophic 
damage of the load banks. 
3.3  TIMER 
3.3.1.  TIME BASE:  
3.3.1.1.  Microprocessor Controlled 
3.3.2.  MODES: 
3.3.2.1.  NORMAL: Timer advances at the rate of one count per minute 
(HH:MM). 
3.3.2.2.  FAST: Timer advances at the rate of one count per second (MM:SS). 
3.3.2.3.  TEST: Timer advances at the rate of 60 counts per second (SS:SS/60).