Precision Trading 60 R3.0 ユーザーズマニュアル

ページ / 62
Operator Manual, Supercharger 60 
R3.0 
 
Page 14 of 62 
3.1.12.1.  3 AMPS idling plus ½ the value of the charging current; e.g. when 
charging 40 AMPS the line current is 23 AMPS (Note: nominal values, 
line voltage and frequency dependent). 
3.2  DISCHARGE 
3.2.1.  CONTROL: Transistors, air cooled. 
3.2.2.  MAXIMUM CURRENT: 
3.2.2.1.  60 AMPS. Total power dissipation must not exceed 1.2KW (1200 
watts, the product of battery voltage and battery current). 
3.2.2.2.  NOTE: Discharge current is automatically limited to 30 AMPS for 
battery voltages in excess of 32 VOLTS. A current fault will be 
generated if attempting to discharge at more than 30 AMPS. 
3.2.3.  MINIMUM INCREMENT:  
3.2.3.1.  0.1 AMP. 
3.2.4.  ACCURACY and STABILITY of settings: 
3.2.4.1.  ±1% of reading, ±0.1AMP. 
3.2.5.  MODES:  
3.2.5.1.  Analysis (automatic cut-off) 
3.2.5.2.  Deep cycle (full discharge).