Gaggenau AR400742 インストールガイド

ページ / 32
6
General notes
Ventilation line
Note: The appliance manufacturer does not assume any 
warranty for complaints attributable to the pipe section.
The appliance achieves its optimum performance by 
means of a short, straight exhaust air pipe and as 
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many 
pipe bends or pipe diameters that are smaller than 
6" (150 mm), the optimum extraction performance is 
not achieved and fan noise is increased.
The pipes or hoses for laying the exhaust air line 
must be made of non-combustible material.
Use sealing strip for deviating pipe diameters.
Electrical Requirements
This appliance must be properly installed and grounded 
by a qualified technician in accordance with the 
National Electrical Code ANSI/ NFPA 70 (latest edition) 
and local electrical code requirements. IN CANADA: 
Electrical installation must be in accordance with the 
current CSA C22.1 Canadian Electrical Codes Part1 
and/or local codes. 
The range must be connected to the proper electrical 
voltage and frequency as specified on the rating plate. 
For wall mounting: Checking the wall
The wall must be level, vertical and adequately load-
bearing.
Use suitable fasteners depending on the type of 
construction (e.g. massive brickwork, drywall, 
porous concrete, Poroton wall tiles).
The depth of the bore holes must be the same 
length as the screws. The wall plugs must have a 
secure grip.
The maximum weight of the fan module is 
approx. 9 kg
.
Before You Begin
Tools and Parts Needed
Screwdriver Torx T20
Pencil
Drill with ¼" (6 mm) bit
Jigsaw
Tape Measure
Note: Additional materials may be necessary for 
installation in solid surface countertops. Contact the 
countertop manufacturer.
Additional parts needed:
1 inch 3-wire conduit
1 inch cable/cord connector 
Parts Included