Installation
Select Location
The proper location will ensure peak 
performance of your appliance. We 
recommend a location where the ice 
machine will be out of direct sunlight 
and away from heat sources. To ensure 
your product performs to specifications, 
the recommended installation location 
temperature range is from 55 to 90°F (13 
to 32°C) for built in ice machines and 55 
to 100°F (13 to 38°C) for freestanding ice 
machines. Ice machines will not perform 
correctly in ambient temperatures less 
than 55°F (13°C). This unit is not intended 
to be installed outdoors.
Cabinet Clearance
Ventilation is required from the bottom 
front of the appliance. Keep this area open 
and clear of any obstructions. Adjacent 
cabinets and counter top can be installed 
around the appliance as long as the front 
grille remains unobstructed.
CAUTION
Do not obstruct the front grille. The 
openings within the front grille allow 
air to flow through the condenser 
heat exchanger. Restrictions to this 
air flow will result in increased energy 
usage and loss of cooling capacity. 
For this reason it is important this 
area not be obstructed and the grille 
openings kept clean. Electrolux does 
not recommend the use of a custom 
made grille as air flow may be 
restricted (Figure 1).
Figure 1
Front Grille,
keep this area
open
Rear
Leveling
Legs
Front Leveling
Legs
CAUTION
PLEASE READ all instructions 
completely before attempting to 
install or operate the unit. Plumbing 
installation must observe all state and 
local codes. All ice makers require 
a connection to the water supply 
and improper hook-up can result 
in substantial property damage! All 
water and drain connections MUST 
BE made by a licensed/qualified 
plumbing contractor. Failure to follow 
recommendations and instructions 
may result in damage and/or harm.
Drain Plumbing
Your ice machine requires drain plumbing.
Follow these guidelines when installing 
drain lines to prevent water from flowing 
back into the ice maker storage bin and/
or potentially flowing onto the floor causing 
water damage.
CAUTION
Observe and follow all local building 
codes when installing this ice 
machine and drain lines.
CL
CL
14
7
8
"
(37.8 cm)
11
16
"
(17mm)
1
1
4
"
(3.2 cm)
4
17
32
"
(11.5 cm)
21
1
2
"
(54.6 cm)
Water 
supply 
inlet
Drain access in
bottom of unit
(if using gravity
drain)
4
3
32
"
(10.4 cm)
Figure 2
Installing the Drain
CAUTION
Failure to use an adequate drainage 
system, will result in surrounding 
water damage and/or poor ice 
production.