Aprilaire 8620 ユーザーズマニュアル

ページ / 11
4
5
WIRINg TERMINAl
Wire specifications:
18-24 gauge thermostat wire
Installation notes:
•  Ensure power at the HVAC equipment is off. 
•  Loosen screw terminals, insert stripped wire and 
re-tighten .
•  Push the excess wire back into the opening and plug 
the wall opening to prevent drafts .
INSTAllATION
I1 & I2 – Indoor Air Quality control output
C – Common (optional when powered by batteries)
O/b – Reversing valve
Y – 1st stage cooling / compressor 
Y2 – 2nd stage cooling / compressor
g – Fan
RC – 24VAC supply cooling
1
R – 24VAC supply heating
1
W2 – 2nd stage heat / auxiliary
W – 1st stage heat / auxiliary
l – System fault indicator (optional) (heat pump only)
S1 & S2 – outdoor temperature sensor (included)
T1 & T2 – remote temperature sensor (optional)
1
 Jumper between RC & R is used in single transformer systems 
(see wiring diagrams).
INSTAllATION
I2
I1
Y
O/B
RC R
G
Y2
W2
L
T2
T1
S1
S2
W
SINglE TRANSfORMER (USE JUMpER WIRE)
TWO TRANSfORMERS (REMOVE JUMpER WIRE)
JUMPE
R
OUTDOOR TEMP  SENSOR
1st HEA
TING
1st COOLING
FA
N
2nd HEA
TING
2nd COOLING
NOT USED
TRANSFORMER
REMOTE TEMP  SENSOR
NOT USED
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
NOT USED
2nd COOLING
2nd HEA
TING
FA
N
1st COOLING
1st HEA
TING
OUTDOOR TEMP  SENSOR
COOLING
HEA
TING
REMOTE TEMP  SENSOR
NOT USED
TRANSFORMER
TRANSFORMER
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
SINglE TRANSfORMER (USE JUMpER WIRE)
TWO TRANSfORMERS (REMOVE JUMpER WIRE)
2nd COMPRESSOR
2nd AUX HEA
TING
FA
N
1st COMPRESSOR
1st AUX HEA
TING
OUTDOOR TEMP  SENSO
R
JUMPER
FAUL
T DETECT
REVERSING 
VA
LV
E
HE
AT
 PUMP
TRANSFORMER
REMOTE TEMP  SENSO
R
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
FAUL
T DETECT
OUTDOOR TEMP  SENSO
R
1st AUX HEA
TING
1st COMPRESSOR
FA
N
2nd AUX HEA
TING
2nd COMPRESSOR
TRANSFORMER
HE
AT
 PUMP
HE
AT
IN
G
TRANSFORMER
REMOTE TEMP
 
SENSO
R
REVERSING 
VA
LV
E
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
CONVENTIONAl HEAT/COOl WIRINg DIAgRAMS
HEAT pUMp WIRINg DIAgRAMS
pOWER & RESET OpTIONS 
The thermostat is dual power . It can either be AC or 
battery powered, or both (to provide backup power for 
the clock). Batteries are optional if your thermostat was 
wired to run on AC power when installed . 
For heat pump systems the C terminal must be connected 
to the common of the 24VAC transformer in order for the 
system fault and emergency heat indicators to operate .
The thermostat has a memory backup that saves the 
thermostat settings in case of a power interruption . The 
system settings will be retained but the clock will reset 
after 90 seconds with no battery or AC power .
The reset button located under the battery cover can 
be used to reset the thermostat to factory defaults . The 
system settings will also be reset to default . 
Note: The reset button is disabled when the thermostat 
is removed from the wall for programming .
RESET
BUTTON