Aprilaire 8620 ユーザーズマニュアル

ページ / 11
6
7
SETUp & TESTINg
INSTAllER SETUp MENU
CHANgE SYSTEM SETTINgS
HOW TO ENTER THE INSTAllER SETUp MENU AND SElECT EQUIpMENT TO SETUp:
In the Installer Setup, HVAC or Indoor Air Quality setup can be selected. If Indoor Air Quality setup is selected, the 
user can then select to set up Air Cleaning, Humidification, Dehumidification or Ventilation.
press [MODE] to set system to OFF. 
press [MENU] to enter main menu . 
press and hold [SETUp] for seven seconds, [INSTAll 
SETUp] appears .
press [INSTAll SETUp] to enter installer setup menu .
press 
 or 
 to adjust the option. 
press [MENU] to exit.
press [NEXT] to select option .
If IAQ (Indoor Air Quality) was selected, 
press 
 or 
 to adjust the Outdoor Sensor setting or IAQ (Indoor 
Air Quality) option .
press [NEXT] to select Outdoor Sensor setting or IAQ 
(Indoor Air Quality) option .
System Settings can now be changed .
press [NEXT] or [bACK] to page through the settings .
press 
 or 
 to adjust the setting. 
press [DONE] to save and exit, or [CANCEl] to exit 
without saving . 
The thermostat will discard changes and exit if nothing 
is pressed within 60 seconds .
To reset the installer settings to the default, reset 
the thermostat by pressing the 
[RESET] button for 5 
seconds .
SETTING 
NUMBER
SETTING 
DESCRIPTION
SETTING 
OPTIONS
EQUIpMENT TYpE SElECTION SWITCH (SW1)
This thermostat has the option of being used in heat 
pump or heat/cool systems . Switch SW1 located on the 
back of the thermostat’s face is used to select this option. 
This setting is displayed in the Installer System Settings 
under Equipment Type .
Note: Thermostat reboots within 10 seconds after switch 
position is changed .
Note: The I1/I2 output is a dry contact closure . The humidifier wiring diagram assumes the control is powering a 
solenoid valve . The dehumidifier wiring diagram is for a normally open dry contact input . The ventilation diagram 
assumes the control is for a normally closed damper. Please see the individual humidifier, dehumidifier or ventilation 
installation instructions for product specific wiring details . 
HC
HP
SW1
HEAT/COOL  
HEAT PUMP
HC
HP
DEHUMIDIfIER WIRINg
HUMIDIfIER WIRINg
VENTIlATION WIRINg
DEHUMIDIFIER
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
HUMIDIFIER
TRANSFORME
R
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
NORMALL
Y CLOSED DAMPER
TRANSFORME
R
G
Y2
Y
O/B
I1
W
RC R W2
S2
L
C
I2
S1 T1 T2
INSTAllATION