2.3.3  Accessing the CLI using a PC + HyperTerminal  
The Command Line Interface (CLI) is accessed using a PC with that includes a terminal 
emulation package such as HyperTerminal
®
NOTE: The device is only accessible through the serial port. 
2.3.4  Configuring the Canopy T1/E1 Multiplexer using the CLI 
Before you use the CLI to configure the Canopy T1/E1 Multiplexer, you must configure 
the PC serial port.  
Procedure 6: Configuring serial port 
Use this procedure to access the CLI using a terminal emulation program such as 
HyperTerminal.
®
1.  Connect the serial cable from the DB9 serial port on a PC to the Serial port on 
the Canopy T1/E1 Multiplexer.  The DB9 connector on Canopy T1/E1 Multiplexer 
is female; the cable from the PC is male.  A straight-through cable is required. 
2.  Start HyperTerminal or another terminal emulation program. 
3.  Set the terminal emulation program to emulate a VT100 terminal with the 
following settings: 
 
Parameter Value 
Bits per second 
19200 
Data bits 
        8 
Parity none 
Stop bits 
        1 
Flow control 
none 
 
4. Press 
Enter. 
 
The Canopy T1/E1 Multiplexer Login menu is displayed. 
RESULT: The signal port is configured. 
 end of procedure 
 
To use the CLI, select Command Line Interface terminal from the File drop-down menu 
(illustrated in 
). The Command Line Interface window opens, as 
shown in 
 
Issue 3