Serial port configuration task list
173
SmartWare Software Configuration Guide 
14 • Serial port configuration
Hardware Port   : V.35
Transmit Edge   : normal
Port Type       : DTE
CRC Type        : CRC-16
Max Frame Length: 2048
Recv Threshold  : 1
Encapsulation   :
Configuring the serial encapsulation type
The synchronous serial interface supports the Frame Relay and PPP serial encapsulation method. For more 
information how to configure Frame Relay and PPP, please see Chapter15,
To set the encapsulation method used by a serial interface, use the 
encapsulation
 interface 
configuration command.
This procedure describes how to set the encapsulation type of the serial interface.
Mode: Administrator execution
Example: Configuring the serial encapsulation type 
The following example enables Frame Relay encapsulation for the serial interface on slot 0 and port 0. Check 
that in the command output of 
show port serial
 Encapsulation is set to framerelay.
node(cfg)#port serial 0 0
node(prt-ser)[0/0]#encapsulation framerelay
node(prt-ser)[0/0]#show port serial
Serial Interface Configuration
------------------------------
Port            : serial 0 0 0
State           : CLOSED
Hardware Port   : V.35
Transmit Edge   : normal
Port Type       : DTE
CRC Type        : CRC-16
Max Frame Length: 2048
Recv Threshold  : 1
Encapsulation   : framerelay
Configuring the hardware port protocol 
Note
Only available on certain devices. 
Step
Command
Purpose
1
node(cfg)#port serial slot port
Selects the serial interface on slot and 
port.
2
node(prt-ser)[slot/port]#[no] encapsulation 
{framerelay | ppp}
Sets the encapsulation type for the 
selected interface.
3
node(prt-ser)[slot/port]#show port serial
Displays the serial interface configuration.