      protocol eam-wink-start
      encapsulation cc-rbs
      bind interface pri00_1_8 switch
  channel-group group_9_16
    timeslots 9-16
    encapsulation rbs
    rbs
      protocol ground-start exchange
      encapsulation cc-rbs
      bind interface pri00_9_16 switch
  channel-group group_17_24
    timeslots 17-24
    encapsulation rbs
    rbs
      protocol eam-double-wink-start
      encapsulation cc-rbs
      bind interface pri00_17_24 switch
port e1t1 0 0
  no shutdown
Example 4: Frame Relay without a channel-group
port e1t1 0 0
  port-type e1
  framing crc4
  encapsulation hdlc
  hdlc
    encapsulation framerelay
    framerelay
      lmi-type itu
      pvc 100
        encapsulation rfc1490
        bind interface pvc100 router
        no shutdown
port e1t1 0 0