Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
PRI port configuration task list
204
SmartWare Software Configuration Guide 
16 • PRI port configuration
Example 5: Framerelay with a channel-group
port e1t1 0 0
  port-type e1
  framing crc4
  encapsulation channelized
  channel-group myGroup
    timeslots 13-17
    encapsulation hdlc
    hdlc
      encapsulation framerelay
      framerelay
        lmi-type itu
        pvc 100
          encapsulation rfc1490
          bind interface pvc100 router
          no shutdown
port e1t1 0 0
  no shutdown
Example 6: PPP without a channel-group
port e1t1 0 0
  port-type e1
  framing crc4
  encapsulation hdlc
  hdlc
    encapsulation ppp
    bind interface myPPP router
port e1t1 0 0
  no shutdown
Example 7: PPP with a channel-group
port e1t1 0 0
  port-type e1
  framing crc4
  encapsulation channelized
  channel-group yourGroup
    timeslots 1,9,16,23
    encapsulation hdlc
    hdlc
      encapsulation ppp
      bind interface myPPP router
port e1t1 0 0
  no shutdown