Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
PRI port configuration task list
202
SmartWare Software Configuration Guide 
16 • PRI port configuration
Example 4: Frame Relay without a channel-group
Example 5: Frame Relay with a channel-group
Example 6: PPP without a channel-group
Example 7: PPP with a channel-group
Example 1: ISDN
port e1t1 0 0
  port-type t1
  clock auto
  linecode b8zs
  framing esf
  encapsulation q921
  q921
    uni-side auto
    encapsulation q931
    q931
      protocol ni2
      uni-side net
      bchan-number-order ascending
      encapsulation cc-isdn
      bind interface pri00 switch
port e1t1 0 0
  no shutdown
Example 2: RBS without a channel-group
port e1t1 0 0
  port-type t1
  clock master
  linecode b8zs
  framing esf
  encapsulation rbs
  rbs
    protocol ground-start exchange
    encapsulation cc-rbs
    bind interface pri00 switch
port e1t1 0 0
  no shutdown
Example 3: RBS with a channel-group
port e1t1 0 0
  port-type t1
  clock master
  linecode b8zs
  framing esf
  encapsulation channelized
  channel-group group_1_8
    timeslots 1-8
    encapsulation rbs
    rbs