ユーザーズマニュアル目次HP 9000 rp3410 and HP 9000 rp3440 User Service Guide1Table of Contents3About This Document15Intended Audience15New and Changed Information in This Edition15Publishing History15Document Organization15Typographic Conventions16HP-UX Release Name and Release Identifier16Related Documents17Contacting HP17Before You Contact HP17HP Contact Information18Subscription Service18Documentation Feedback181 Overview19HP 9000 rp3410 and rp3440 Server Views19Detailed Server Description20Processor20Memory20PCI Riser21Internal Core I/O21External Core I/O21Power Supply Unit21System Board Manageability22Enhanced Server Manageability Using the iLO MP22Hard Disk Drives22Internal RAID22Firmware22Event IDs for Errors and Events23Dimensions and Values23System Board23System Board Components24PA RISC Processor24Processor Bus25ZX1 I/O and Memory Controller25Memory25Memory Architecture26DIMMs26Memory Array Capacities26Chip Spare Functionality27Serial Presence Detect27I/O Bus Interface27Processor Dependent Hardware Controller27Field Programmable Gate Array28BMC28SCSI Controller28IDE Interface291 GB System LAN29USB Connectors29Disk and I/O Path Logging29Controls, Ports, and LEDs31Control Panel31Additional Controls and Indicators33Hot-Pluggable Disk Drive Indicators33Optional Removable Media Drive33Rear Panel3410/100/1000 Base-T Ethernet LAN Connector35USB Ports35SCSI Port, Ultra 3, 68-Pin36iLO MP Card LAN LEDs37Powering the Server On and Off38Power States38Powering On the Server39Powering On the Server Using the iLO MP39Powering On the Server Manually39Powering Off the Server39Powering Off the Server Using the iLO MP39Powering Off the Server Manually402 System Specifications41System Configuration41Dimensions and Values41Grounding42Electrical Specifications42AC Power Cables42Circuit Breaker42System Power Specifications43Power and Cooling43Environmental Specifications44Operating Environment44Environmental Temperature Sensor45Nonoperating Environment45Cooling45CPU and Memory Cooling45Bulk Power Supply Cooling45PCI and Mass Storage Section Cooling45Acoustic Noise Specification46Physical and Environmental Specifications463 Installing the System47Introduction47Server Views47Detailed Server Description48Features48Firmware49Event IDs for Errors and Events49Dimensions and Values49Safety Information50Installation Sequence and Checklist50Unpacking and Inspecting the Server51Verifying Site Preparation51Inspecting the Shipping Containers for Damage51Unpacking the Server51Checking the Inventory51Returning Damaged Equipment52Unloading the Server with a Lifter52Installing Additional Components52Removing and Replacing Server Covers and Bezels52Rack-Mounted Server52Accessing a Rack-Mounted Server52Extend the Server From the Rack53Insert the Server Into the Rack53Removing and Replacing the Top Cover on a Rack-Mounted Server53Removing the Top Cover on a Rack-Mounted Server54Replacing the Top Cover on a Rack-Mounted Server54Removing and Replacing the Front Bezel on a Rack-Mounted Server55Removing the Front Bezel on a Rack-Mounted Server55Replacing the Front Bezel on a Rack-Mounted Server56Accessing a Pedestal-Mounted Server57Removing the Side Cover on a Pedestal-Mounted Server57Removing the Top Cover on Pedestal-Mounted Server57Replacing the Top Cover on a Pedestal-Mounted Server58Replacing the Side Cover on a Pedestal-Mounted Server59Removing and Replacing the Front Bezel on a Pedestal-Mounted Server60Removing the Front Bezel on a Pedestal-Mounted Server60Replacing the Front Bezel on a Pedestal-Mounted Server60Installing Internal Hard Disk Drives61Installing a DVD Drive64Installing the DVD Drive64Removing and Replacing Airflow Guides65Removing and Replacing the Memory Airflow Guide65Removing the Memory Airflow Guide65Replacing the Memory Airflow Guide66Removing and Replacing the Processor Airflow Guide66Removing the Processor Airflow Guide66Replacing the Processor Airflow Guide69Installing Additional System Memory70Supported DIMM Sizes70Installing System Memory71rp3410 Memory Configuration71Memory Loading Rules and Performance Guidelines72rp3440 Memory Configuration72Memory Loading Rules and Performance Guidelines72System Firmware Requirements72Installation Procedure73Removing and Replacing the PCI Card Cage74Removing the PCI Card Cage74Replacing the PCI Card Cage75Installing PCI Cards75Installing a PCI Card76Installing an Additional Power Supply76Installing an Additional Processor Module78Replacing the System Battery85Battery Notice85Replacing the System Battery85Installing the Server Into a Rack, Non-HP Rack, or Pedestal86HP Rack87Non-HP Rack87Pedestal Mount87Connecting the Cables87AC Input Power87Core I/O Connections87Applying Standby Power To the Server88Connecting To the LAN88Console Setup89Setup Checklist89Setup Flowchart90Preparation91Determining the Physical iLO MP Access Method91Determining the iLO MP LAN Configuration Method92Configuring the iLO MP LAN Using DHCP and DNS92Configuring the iLO MP LAN Using ARP Ping93Configuring the iLO MP LAN Using the RS-232 Serial Port94Logging In to the iLO MP95Additional Setup96Modifying User Accounts and Default Password96Setting Up Security97Security Access Settings97Accessing the Host Console97Accessing the Host Console With the TUI - CO Command97Interacting With the iLO MP Using the Web GUI98Accessing the Graphic Console Using VGA99Enabling VGA Graphics Capability99Installing Your A6150B Graphics Card100Connecting a Monitor Using the VGA Port100Powering the Server ON and OFF100Power States100Powering On the Server101Powering On the Server Using the iLO MP PC Command101Powering On the Server Manually101Powering Off the Server101Powering Off the Server Using the iLO MP PC Command102Powering Off the Server Manually102Booting the Operating System102Supported Operating System102Booting and Shutting Down HP-UX102Standard HP-UX Booting Using the Boot Console Handler102Booting HP-UX in Single-User Mode103Booting HP-UX in LVM Maintenance Mode103Shutting Down HP-UX103Verifying the Server Configuration Using Boot Console Handler104Troubleshooting104Troubleshooting Methodology104Troubleshooting Using the Server Power Button104Server Does Not Power On105Operating System Does Not Boot105Operating System Boots with Problems106Intermittent Server Problems106DVD Problems106Hard Drive Problems106Console Problems106Downloading and Installing the Latest Version of the Firmware106Downloading the Latest Version of the Firmware107Installing the Latest Version of the Firmware107Troubleshooting Using LED Indicators107Front Control Panel LEDs107Information to Collect Before You Contact Support1084 Booting the Operating System109Supported Operating System109Booting and Shutting Down HP-UX109Standard HP-UX Booting Using the Boot Console Handler109Booting HP-UX in Single-User Mode110Booting HP-UX in LVM Maintenance Mode110Shutting Down HP-UX110Verifying the Server Configuration Using Boot Console Handler1115 Troubleshooting113Troubleshooting Methodology113Troubleshooting System Power113Using the Front Panel Power Button113Operating System Does Boot114Operating System Does Not Boot114Troubleshooting Using Online Support Tools114Support Tools Manager114Event Monitoring Service114iLO MP115Accessing the iLO MP Interface and System Logs115SEL115Troubleshooting Using Offline Support Tools116Offline Diagnostic Environment116Identifying and Diagnosing Hardware Problems117Troubleshooting Using LEDs117Power and System LEDs118LAN LEDs118System Board LEDs119Cleaning Procedures1206 Removing and Replacing Components123Safety Information123Required Service Tools123Location of Internal Components and Connectors123Removing and Replacing Server Covers and Bezel126Accessing a Rack-Mount Server126Extending the Server From the Rack126Inserting the Server Into the Rack127Removing and Replacing the Top Cover on a Rack-Mounted Server127Removing the Top Cover on a Rack-Mounted Server127Replacing the Top Cover on a Rack-Mounted Server128Removing and Replacing the Front Bezel on a Rack-Mounted Server129Removing the Front Bezel129Replacing the Front Bezel129Accessing a Pedestal-Mount Server130Removing the Side Covers on a Pedestal-Mounted Server130Replacing the Top and Side Covers on a Pedestal-Mounted Server132Removing and Replacing the Front Bezel on a Pedestal-Mounted Server134Removing the Front Bezel134Replacing the Front Bezel on a Pedestal-Mounted Server135Removing and Replacing System Fans136Removing a System Fan136Replacing a System Fan138Removing and Replacing the Power Supply138Removing the Power Supply138Replacing the Power Supply139Removing and Replacing an Internal Hard Disk Drive140Removing a Hard Disk Drive140Replacing a Hard Disk Drive142Removing and Replacing Airflow Guides144Removing and Replacing the Memory Airflow Guide144Removing the Memory Airflow Guide144Replacing the Memory Airflow Guide145Removing and Replacing the Processor Airflow Guide145Removing the Processor Airflow Guide145Replacing the Processor Airflow Guide148Removing and Replacing System Memory149Supported DIMM Sizes149rp3410 Memory Configuration150Memory Loading Rules151rp3440 Memory Configuration151Memory Loading Rules151System Firmware Requirements151Replacing Deallocated Memory Ranks151Removing System Memory152Installing System Memory152Removing and Replacing a Dual Processor Module155Removing a Dual Processor Module155Installing a Dual Processor Module160Removing and Replacing the System Battery165Battery Notice165Removing the System Battery165Replacing the System Battery166Removing and Replacing the PCI Card Cage167Removing the PCI Card Cage167Replacing the PCI Card Cage168Removing and Replacing PCI Cards169Removing a PCI or Graphics Card169Replacing a PCI or Graphics Card170Removing and Replacing the PCI Backplane171Removing the PCI Backplane171Replacing the PCI Backplane171Removing and Replacing a Removable Media Drive172Removing a Removable Media Drive172Replacing a Removable Media Drive173Removing and Replacing the iLO MP Card173Removing the iLO MP Card173Replacing the iLO MP Card174Removing and Replacing the iLO MP Card Battery175Battery Notice175Removing the iLO MP Card Battery175Replacing the iLO MP Card Battery176Removing and Replacing the LED Status Panel176Removing the LED Status Panel176Replacing the LED Status Panel177Removing and Replacing the System Board177Removing the System Board177Replacing the System Board180Replacing the Resident System Board with a Replacement System Board184Replacing a System Board185Removing and Replacing the Power Supply Interface Module186Removing the Power Supply Interface Module186Replacing the Power Supply Interface Module187Removing and Replacing the Hard Disk Drive (SCSI) Backplane189Removing the Hard Drive Disk SCSI Backplane189Replacing the Hard Disk Drive SCSI Backplane191A Replacement Parts193Parts Illustrations193Customer Self Repair194Replaceable Parts List195B Utilities199Boot Console Handler199BCH Commands199BCH Main Menu Commands and Submenus200Boot Command200Path Command200Search Command201Configuration Menu201Information Menu202Service Menu203Display Command203SCSI Command203ProductNum Command203iLO MP203C Physical and Environmental Specifications205Index207サイズ: 10.8MBページ数: 210Language: Englishマニュアルを開く