Quadra-Fire CASTINS-CSB 사용자 설명서

다운로드
페이지 52
R
August 20, 2009
250-7251G
Page  25
Castile Pellet Insert
B.  General Operating Information
1.  Thermostat Calls For Heat
The appliance is like most modern furnaces; when the thermostat 
calls for heat, your appliance will automatically light and deliver 
heat.  When the room is up to temperature and the thermostat 
is satisfi ed, the red call light will shut off  and the appliance will 
shut down.  The red call light is located behind the left access 
panel.
Figure 25.1
2.  Heat Output Controls
This appliance is equipped with a heat output control switch that 
has three settings or burn rates; low, medium and high.  The 
appliance will turn on and off as the thermostat demands.  When 
the thermostat calls for heat, the appliance will always start up 
on High.  After burning approximately 4 minutes, the appliance 
will then burn at the rate at which it was originally set.  If the 
appliance is set at one of the lower settings, it will run quieter 
but takes longer to heat up an area than if it were set at a higher 
burn rate.  Regardless of the burn rate, when the area is warm 
enough to satisfy the thermostat, the appliance will shut off.
Heat Output
Switch
Reset Button
Ash Pan
Right
Side
C.  Before Your First Fire
1.  First,  make  sure  your  appliance  has  been  properly 
installed and that all safety requirements have been met.  
Pay particular attention to the fi re protection, venting and 
thermostat installation instructions.
2.  Double check that the ash pan and fi rebox are empty!
3.  Check the position of the thermocouple, located above 
the fi repot, and make sure that it protrudes approximately 
3/4 inch (19mm) into the fi repot.  
4.  Close the front door.  
E.  Fire Characteristics
A properly adjusted fi re with the heat output control switch 
set on “HIGH” has a short active fl ame pattern that extends 
out of the fi repot approximately 4 inches (102mm).  If the fi re 
has tall fl ames with black tails and seems somewhat lazy, the 
feed rate will need to be reduced.  If the fi re is not 4 inches 
(102mm)  tall,  increase  the  feed  rate.    A  medium  and  low 
setting will give a shorter fl ame.  The fl ame will rise and fall 
somewhat.  This is normal. 
D.  Starting Your First Fire
1.  A  thermostat  is  required  for  proper  operation  of  this 
appliance, except for corn.  At this time, fi ll the hopper 
with pellets, set the thermostat to its lowest setting.  Plug 
the power cord into nearby outlet.
2.  The  exhaust  blower  will  stay  on  for  approximately  18 
minutes  even  though  the  thermostat  is  not  calling  for 
heat.  This is normal.
3.  Locate the heat output control switch behind the right face 
on  the  lower  right  side  of  the  fi rebox.    Set  to  the  HIGH 
setting and then adjust the thermostat to its highest setting.  
The red call light will be on which is located on the top of 
the junction box behind the right cast side.  This indicates 
the thermostat is calling for heat.  Figure 25.1. 
4.  The fuel feed system and the igniter should now be on.
5.  For your fi rst fi re it will be necessary to press the reset 
button once a minute until pellets start to drop into the 
fi repot, then press button 1 more time.  This will fi ll the 
feed system and allow the appliance to begin dropping 
pellets.  The appliance will continue to run as long as the 
thermostat is calling for heat.
6.  Once the appliance has ignited, let it burn for approximately 
15 minutes, then set the thermostat to the desired room 
temperature.  Adjust the heat output control switch to the 
desired setting. 
CAUTION
Tip of thermocouple must be in contact with the inside 
end of the thermocouple cover.
Missed ignitions can occur.
WARNING
Fire Hazard.
Keep combustible materials, gasoline 
and other fl ammable vapors and liquids 
clear of appliance.
•  Do NOT store fl ammable materials in the appliance’s 
vicinity.
•  DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE, 
CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO 
START OR “FRESHEN UP” A FIRE IN THIS HEATER. 
•  DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS 
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
•  DO NOT USE CHEMICALS OF FLUIDS TO START THE 
FIRE. 
•  Keep all such liquids well away from the heater while it is in 
use.
•  Combustible materials may ignite.