Quadra-Fire CASTINS-CSB 사용자 설명서

다운로드
페이지 52
Page  26
250-7251G
August 20, 2009
R
Castile Pellet Insert
The fuel adjustment control rod is factory set, and should be 
adequate for most fuels.  
The set screw is located at the bottom of the hopper and 
set loose at the factory so the fuel adjustment control rod 
will slide by only loosening the wing nut.  Do not re-tighten 
bottom set screw. 
However, if the flame height is too high or too low, you will 
need to adjust the feed rate. Wait until the appliance has been 
burning for 15 minutes before making your adjustments and 
allow 15 minutes for feed adjustment to take effect.  Make 
adjustments in approximately 1/2 inch increments.
1.  Loosen the wing nut.  Figure 26.1.
2.  Adjust  the  fuel  adjustment  control  rod  towards  the  
"+"    symbol  to  increase  the  feed  rate  and  fl ame  height  or 
towards the  "-"  symbol, to decrease the feed rate and fl ame 
height.
3.  Re-tighten the wing nut.
F.  Feed Rate Adjustment
Figure 26.1
Control Box
Junction Box
Reset Button
Heat Output
Switch
Power Cord
Outlet
Thermostat
Block
Fuse
Red Call
Light
Red/Green Light
Blue Light
Wing Nut
"+"
"-"
G.  Iginition Cycles
1.  During each ignition cycle, it is normal to see some smoke 
in the fi rebox.  The smoke will stop once the fi re starts.
2.  The convection blower will automatically turn on after your 
appliance has reached the set temperature.  This blower 
transfers heat from your appliance into the room, and will 
continue to run after the thermostat has stopped calling 
for heat until the appliance has cooled down.
3.  Occasionally the appliance may run out of fuel and shut 
itself  down.    When  this  happens,  the  red  call  light  will 
be on.  To restart it, fi ll the hopper and press the reset 
button. Figure 26.2.  When you press the reset button 
the red call light will go out.  Release the button and the 
light will come back on.  You should see a fi re shortly.  
If not, follow the instructions on page 25, “Starting Your 
First Fire”.
WARNING
Fire Risk
Do NOT operate appliance:
•  With appliance door open.
•  Firepot fl oor open.
•  Cleaning slide plates open.
Do NOT store fuel:
•  Closer than required clearances to com-
bustibles to appliance
•  Within space required for loading or ash 
removal.
Back side of Firepot
Firepot floor left open
Figure 26.2 - DO NOT LEAVE FIREPOT FLOOR OPEN
Figure 26.1