Regency Wraps F33 사용자 설명서

다운로드
페이지 28
16
Regency
®
 F33-3 Freestanding Gas Stove
GENERAL FLUE MAINTENANCE
Conduct an inspection of the fl ue system at least annually. Recom-
mended areas to inspect are:
1)  Check areas of the Flueing System which are exposed to the ele-
ments for corrosion. These will appear as rust spots or streaks, and 
in extreme cases, holes. These components should be replaced 
immediately.
2)  Remove the Cap, and shine a fl ashlight down the Flue. Remove 
any birds nests, or other foreign material.
3)  Check for evidence of excessive condensation, such as water 
droplets forming in the liner, and subsequently dripping out the 
joints, Continuous condensation can cause corrosion of caps, 
pipe, and fi ttings. It may be caused by having excessive lateral 
runs, too many elbows, or exterior portions of the system being 
exposed to cold weather.
4)  Inspect joints, to verify that no pipe sections or fi ttings have been 
disturbed, and consequently loosened. Also check mechanical 
supports such as Wall Straps for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs. Turn off the gas valve 
and allow the unit to cool before opening door to carefully remove 
the logs. The pilot light generates enough heat to burn someone. If 
for any reason a log should need replacement, use only Regency
®
 
replacement logs. The position of these logs must be as shown in the 
diagram under Log Installation.  
NOTE:  Improper positioning of logs may create 
carbon build-up and will alter the unit’s performance 
which is not covered under warranty.
GOLD-PLATED DOORS
The 24 carat gold plated fi nish on the door requires little maintenance, 
and need only be cleaned with a damp cloth.  DO NOT use abrasive 
materials or chemical cleaners, as they may harm the fi nish and void the 
warranty. Clean any fi ngerprints off  before turning the unit on.
GLASS REPLACEMENT
Your F33-3 stove is supplied with high temperature, 5 mm Neoceram 
silica coated ceramic glass that will withstand the highest heat that your 
unit will produce.  In the event that you break your glass by impact, 
purchase your replacement glass from an authorized Regency
®
 dealer 
only, and follow our step-by-step instructions for replacement.
1)  Allow the stove to cool before removing or replacing glass.
2)  To remove the door from the stove remove the securing screw lo-
cated between the ashlip and the door, then unfasten the latch.
3)  Remove gold hinge caps from door.
4)  Lift door off hinge and lay door on a soft, fl at surface.
5)  Remove the screws in the glass retainer clips and remove the glass 
retainer rod. Remove any remaining pieces of glass and ensure 
that the door is free of debris. Use caution when removing broken 
glass to avoid injury.
6)  Install the door screen (Australia only).
7)  Install the replacement glass. When placing the replacement glass 
in the door, make sure that the glass gasketing will properly seal 
your unit.
8)  Put glass in place and then position glass retainer rod.
Note:  Do not use substitute materials. If your glass does 
break, do not continue to use your unit until it has been 
replaced.
9)  Position the glass retainer clips and door securing bracket. Secure 
the glass retaining screws but do not overtighten as this may cause 
the glass to break after the unit heats up.
10) Tighten all screws evenly. Do not overtighten as this may cause 
breakage.
11)  Slip door over hinge pins and put hinge caps back onto door. Latch  
door securely using the handle and secure the security bracket 
with the screw.
MAINTENANCE
NOTE: Door Screen only in Australia.