REMOVING VALVE ASSEMBLY
1)  Shut off gas supply.
2)  If optional fan is installed, disconnect power source to stove.
3)  Remove access panel.
 a) Front panel on pedestal model.  See diagram 1.
 b) Panel from bottom of leg shield.  See diagram 2.
Note: 
Access panel only has to be loosened to be taken out.
Diagram 1
Diagram 2
AERATION ADJUSTMENT
The burner aeration is factory set. Adjustment may be needed due to the 
local gas supply or altitude. As a general rule if the fl ame is too yellow 
open up the air shutter, if it is too blue close the air shutter.
  
NG 
11 
mm
  
LPG 
wide 
open
Note: 
This adjustment only to be made by an authorised
  person.   
PILOT ADJUSTMENT
Periodically check the pilot fl ames. Correct fl ame pattern has three 
strong blue fl ames: 1 fl owing around the thermopile, 1 around the 
thermocouple and 1 fl owing across the burner (it does not have 
to be touching the burner).
Note: 
If you have an incorrect fl ame pattern, contact your 
Regency
®
 dealer for further instructions.
 
MAINTENANCE
Incorrect fl ame pattern will have small, probably yellow fl ames, 
not coming into proper contact with the rear burner or thermopile 
or thermocouple. 
 
Top View of pilot fl ame
Top View of pilot fl ame
THERMOPILE/THERMOCOUPLE 
REPLACEMENT
1)  Loosen the thermocouple or thermopile with a 9mm spanner at 
bracket.
2)  Disconnect thermocouple by loosening nut from the valve with 
a 9mm spanner. Disconnect thermopile by loosening 2 screws 
marked TP on the valve.
3)  Drop the thermocouple or thermopile down from the bracket and 
pull it out of the unit.
4)  Reinstall the new ones in reverse order.