15
CHIMNEY 
Your  wood  stove  may  be  hooked  up  with  a  factory  built  or  masonry  chimney.    If  you  are 
using a factory built chimney, it must comply with UL 103 or ULC S629 standards; therefore 
it must be a Type HT (2100°F).  It is extremely imp ortant that it be installed according to the 
manufacturer's specifications. 
 
If  you  are  using  a  masonry  chimney,  it  is  important  that  it  be  built  in  compliance  with  the 
specifications of the National Building Code.  It must be lined with fire clay bricks, metal or 
clay tiles sealed together with fire cement.  (Round flues are the most efficient). 
 
The interior diameter of the chimney flues must be identical to the stove's smoke exhaust.  
A  flue  which  is  too  small  may  cause  draught  problems,  while  a  large  flue  favours  rapid 
cooling of the gas, and hence the build-up of creosote and the risk of chimney fires.  Note 
that  it  is  the  chimney  and  not  the  stove  which  creates  the  draught  effect;    your  stove's 
performance is directly dependent on an adequate draught from your chimney. 
 
The following recommendations may be useful for the installation of your chimney: 
 
1.  Do not connect this unit to a chimney flue serving another appliance. 
2.  It  must  rise  above  the  roof  at  least  3'  (0.9  mm)  from  the  uppermost  point  of 
contact. 
3.  The chimney must exceed any part of the building or other obstruction within a 10' 
(3.04 m) distance by a height of 2' (0.6 m). 
4.  Installation  of  an  interior  chimney  is  always  preferable  to  an  exterior  chimney.  
Indeed, the interior chimney will, by definition, be hotter than an exterior chimney, 
being  heated  up  by  the  ambient  air  in  the  house.    Therefore  the  gas  which 
circulates  will  cool  more  slowly,  thus  reducing  the  build-up  of  creosote  and  the 
risk of chimney fires. 
5.  The  draught  caused  by  the  tendency  for  hot  air  to  rise  will  be  increased  with  an 
interior chimney. 
6.  Using  a  fire  screen at the extremity of the chimney requires regular inspection in 
order to insure that it is not obstructed thus blocking the draught, and it should be 