CHIMNEY CONNECTOR (STOVE PIPE) 
Your chimney connector and chimney must have the same diameter as the stove outlet.  If 
this is not the case, we recommend you contact your dealer in order to insure there will be 
no problem with the draught. 
The  stove  pipe  must  be made of aluminized or cold roll steel with a minimum thickness of 
0.021" or 0.53 mm.  It is strictly forbidden to use galvanized steel. 
Your smoke pipe should be assembled in such a way that the male section of the pipe faces 
down.  Attach each of the sections to one another with three equidistant metal screws. 
The  pipe  must  be  short and straight.  All sections installed horizontally must slope at least 
1/4 inch per foot, with the upper end of the section toward the chimney. 
To insure a good draught, the total length of the coupling pipe should never exceed 8' to 10' 
(24  to  3.04  m).    (Except  for  cases  of  vertical  installation,  cathedral-roof  style  where  the 
smoke exhaust system can be much longer and connected without problem to the chimney 
at the ceiling of the room). 
There should never be more than two 90 degrees elbow in the smoke exhaust system. 
Installation  of  a  "barometric  draught  stabiliser"  (fireplace  register)  on  a  smoke  exhaust 
system is prohibited. 
Furthermore,  installation  of  a  draught  damper  is  not  recommended.  Indeed,  with  a 
controlled  combustion  wood  stove, the draught is regulated upon intake of the combustion 
air in the stove and not at the exhaust. 
 
 