SJ300 Inverter
Configur
ing Dr
iv
P
a
ra
met
e
rs
3–45
Free-setting
V/f Pattern
The free-setting V/f inverter mode of operation uses voltage and frequency parameter pairs to 
define seven points on a V/f graph. This provides a way to define a multi-segment V/f curve 
that best suits your application.
The frequency settings do require that F1 
≤ F2 ≤ F3 ≤ F4 ≤ F5 ≤ F6 ≤ F7; their values must have 
this ascending order relationship. To satisfy this criterion during initial parameter editing, set 
F7 (B012) and work backwards when setting these values, since the defaults are all 0 Hz. 
However, the voltages V1 to V7 may either increase or decrease from one to the next. There-
fore, you may set these parameters in any order.
“B” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
B100
Free-setting V/f
frequency (1)
V/f point 1, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b101 FREE-V/F
V1        000.0V
B101
Free-setting V/f
voltage (1)
V.F point 1, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b102 FREE-V/F
F1        0000Hz
B102
Free-setting V/f
frequency (2)
V/f point 2, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b103 FREE-V/F
V2        000.0V
B103
Free-setting V/f
voltage (2)
V.F point 2, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b104 FREE-V/F
F2        0000Hz
B104
Free-setting V/f
frequency (3)
V/f point 3, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b105 FREE-V/F
V3        000.0V
B105
Free-setting V/f
voltage (3)
V.F point 3, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b106 FREE-V/F
F3        0000Hz
B106
Free-setting V/f
frequency (4)
V/f point 4, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b107 FREE-V/F
V4        000.0V
B107
Free-setting V/f
voltage (4)
V.F point 4, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b108 FREE-V/F
F4        0000Hz
B108
Free-setting V/f
frequency (5)
V/f point 5, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b109 FREE-V/F
V5        000.0V
B109
Free-setting V/f
voltage (5)
V.F point 5, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b110 FREE-V/F
F5        0000Hz
B110
Free-setting V/f
frequency (6)
V/f point 6, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b111 FREE-V/F
V6        000.0V
B111
Free-setting V/f
voltage (6)
V.F point 6, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b112 FREE-V/F
F6        0000Hz
B112
Free-setting V/f
frequency (7)
V/f point 7, frequency 
coordinate
✘ ✘
0.
0.
0.
Hz
>b113 FREE-V/F
V7        000.0V
B113
Free-setting V/f
voltage (7)
V.F point 7, voltage coordi-
nate
✘ ✘
0.0
0.0
0.0
V
>b114 FREE-V/F
F7        0000Hz