SJ300 Inverter
Configur
ing Dr
iv
P
a
ra
met
e
rs
3–47
“C” Group: Intelligent Terminal Functions
The eight input terminals [1], [2], [3], [4], [5], [6], [7], and [8] can be configured for any of 44 
different functions. The next two tables show how to configure the eight terminals. The inputs 
are logical, in that they are either OFF or ON. We define these states as OFF=0, and ON=1.
The inverter comes with default options for the eight terminals. These default settings are 
initially unique, each one having its own setting. Note that European and US versions have 
different default settings. You can use any option on any terminal, and even use the same option 
twice to create a logical OR (though usually not required).
Input Terminal 
Configuration
Functions and Options –The function codes in the following table let you assign one of 44 
options to any of the eight logic inputs for the SJ300 inverters. The functions C001 through 
C008 configure the terminals [1] through [8] respectively. The “value” of these particular 
parameters is not a scalar value, but it is a discrete number that selects one option from many 
available options.
For example, if you set function C001=01, you have assigned option 01 (Reverse Run) to 
terminal [1]. The option codes and the specifics of how each one works are in Chapter 4.
“C” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
C001
Terminal [1] function
44 programmable 
functions available 
for terminals (see 
next section)
✘ ✔
18
[RS]
18
[RS]
18
[RS]
>C001 IN-TM
1          RS
C002
Terminal [2] function
✘ ✔
16
[AT]
16
[AT]
16
[AT]
>C002 IN-TM
2          AT
C003
Terminal [3] function
✘ ✔
06
[JG]
06
[JG]
06
[JG]
>C003 IN-TM
3          JG
C004
Terminal [4] function
✘ ✔
11
[FRS]
11
[FRS]
11
[FRS]
>C004 IN-TM
4          FRS
C005
Terminal [5] function
✘ ✔
09
[2CH]
09
[2CH]
09
[2CH]
>C005 IN-TM
5          2CH
C006
Terminal [6] function
✘ ✔
03
[CF2]
13
[USP]
03
[CF2]
>C006 IN-TM
6          USP
C007
Terminal [7] function
✘ ✔
02
[CF1]
02
[CF1]
02
[CF1]
>C007 IN-TM
7          CF1
C008
Terminal [8] function
✘ ✔
01
[RV]
01
[RV]
01
[RV]
>C008 IN-TM
8          RV