External Signal 
for DC Injection 
Braking
When the terminal [DB] is turned ON, the 
DC braking [DB] feature is enabled. Set the 
following parameters when the external DC 
braking terminal is to be used:
• A053 – DC braking delay time setting. 
The range 0.0 to 5.0 seconds.
• A054 – DC braking force setting. The 
range is 0 to 100%. 
The scenarios to the right help show how 
DC braking works in various situations. 
1. Scenario 1 – The [FW] Run or [RV] 
Run terminal is ON. When the [DB] 
terminal turns ON, DC braking is 
applied. When the [DB] terminal turns 
OFF again, the inverter output ramps to 
the previous frequency.
2. Scenario 2 – The Run command is 
applied from the operator keypad. When 
the [DB] terminal turns ON, DC braking 
is applied. When the [DB] terminal 
turns OFF again, the inverter output 
remains OFF.
3. Scenario 3 – The Run command is 
applied from the operator keypad. When 
the [DB] terminal turns ON, DC braking 
is applied after the delay time set by 
A053 expires. The motor is in a free-
running (coasting) condition during this 
delay time. When the [DB] terminal 
turns OFF again, the inverter output 
remains OFF.
Opt.
Code
Symbol
Function Name
Input 
State
Description
07
DB
External Signal for 
DC Injection 
Braking
ON
applies DC injection braking during 
deceleration
OFF
does not apply DC injection braking 
during deceleration
Valid for 
inputs:
C001, C002, C003, C004, 
C005, C006, C007, C008
Required 
settings:
A053, A054
Notes: 
• 
Do not use the [DB] input continuously or for 
a long time when the DC braking force 
setting A054 is high (depends on the motor 
application).
• Do not use the [DB] feature for continuous or 
high duty cycle as a holding brake. The [DB] 
input is designed to improve stopping perfor-
mance. Use a mechanical brake for holding a 
stop position.
Output
frequency
[FW, RV]
[DB]
Scenario 1
Output
frequency
Run command 
from operator)
Scenario 2
Output
frequency
Scenario 3
[DB]
Run command 
from operator)
[DB]
A053
t
t
t
delay
5
3
1
7
6
4
2
8