Using Intelligent Output Terminals
Oper
ations
a
nd Moni
tor
ing
4–46
Overload 
Advance Notice 
Signal
When the output current exceeds a 
preset value, the [OL] or [OL2] 
terminal signal turns ON. The parame-
ter C041 (or C111, respectively) sets 
the overload threshold. The overload 
detection circuit operates during 
powered motor operation and during 
regenerative braking. The output 
circuits use open-collector transistors, 
and are active low.
NOTE: The example circuit in the table above drives a relay coil. Note the use of a diode to 
prevent the negative-going turn-off spike generated by the coil from damaging the inverter’s 
output transistor.
Opt.
Code
Symbol
Function Name
Output 
State
Description
03
OL
Overload advance 
notice signal (1)
ON
when output current is more than the set 
threshold for the overload signal (C041)
OFF
when output current is less than the set 
threshold for the overload signal (C041)
26
OL2
Overload advance 
notice signal (2)
ON
when output current is more than the set 
threshold for the overload signal (C111)
OFF
when output current is less than the set 
threshold for the overload signal (C111)
Valid for 
outputs:
11, 12, 13, 14, 15,
AL0 – AL2
Required 
settings:
C041, C111
Notes: 
• 
The default value is 100%. To change the 
level from the default, set C041 or 
C111(overload level).
• The accuracy of this function is the same as 
the function of the output current monitor on 
the [FM] terminal (see 
).
Set 
value
[OL] 
Signal
C041
C041
ON
ON
t
Current
threshold
power running
regeneration
threshold
RY
+
See I/O specs on page 
.
Inverter output terminal circuit
CM2
13
14
15
11
12
Example: (Default output configuration 
shown—see pag
OL