Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
Communications Protocol
Append
ix
 B
B–10
Command – 04
The 04 command reads the status of the inverter. 
The frame format of command 04 follows the 
diagrams and specification tables. The transmit 
frame has no data field.
The receive frame has an 8-byte data field, 
containing values for three trip items (plus a 
reserved field).
Trip data is organized as shown. The 
table below lists the codes and their 
meanings.
Element
Description
Size
Value
STX
Control code (STart of TeXt)
1 byte
STX (0x02)
Node
Node (station) address of inverter
2 bytes 01 to 32
Command
Transmission command
2 bytes 04
BCC
Block check sum code
2 bytes Exclusive OR of Node, 
Command, and Data
[CR]
Control code (carriage return)
1 byte
[CR] (0x0D)
Element
Description
Size
Value
STX
Control code (STart of TeXt)
1 byte
STX (0x02)
Node
Node (station) address of inverter
2 bytes 01 to 32
Data
Transmission data
8 bytes (see next table)
BCC
Block check sum code
2 bytes Exclusive OR of Node, 
Command, and Data
[CR]
Control code (carriage return)
1 byte
[CR] (0x0D)
Code
Status A Definition
Status B Definition
Status C Definition
00
Initial status
On stopping
01
On running
Stop
02
On Stopping
On tripping
Deceleration speed
03
On running
Constant speed
04
On free-run stop
Acceleration speed
05
On jog
Forward
06
On dynamic braking
Reverse
07
On retry
Reverse from forward
08
On trip
Forward from reverse
09
On under-voltage
Forward start
10
Reverse start
STX Node
Command
BCC [CR]
Transmit frame format
STX Node
Data
BCC [CR]
Receive frame format
Data field contents
(reserved)
Status C
Status B
Status A