Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
Communications Protocol
Append
ix
 B
B–12
For Command 05, bytes 2, 3, and 4 of 
the event history are status codes A, B, 
and C, respectively. The tables below 
provide status code descriptions.
Code
Status A Definition
Status C Definition
00
Initial status
On reset
01
On stopping
02
On Stopping
On deceleration
03
On running
Constant speed
04
On free-run stop
On acceleration
05
On jog
On 0 Hz running
06
On dynamic braking
On running
07
On retry
On dynamic braking
08
On trip
On overload restriction
09
On under-voltage
Bit
Status B Definition
Error 
Code
0
Ground fault
E14
1
IGBT error, U phase
E30
2
Under-voltage error
E09
3
Over-voltage protection
E07
4
Thermal  trip
E21
5
IGBT error, V phase
E30
6
IGBT error, W phase
E30
7
Gate array error
E23
Data field contents
Status C
Status B
Status A
byte 4
byte 3
byte 2