Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
Step-by-Step Basic Installation
In
v
e
rt
er Moun
ting
and Install
a
tion
2–16
Terminal
Dimensions and 
Torque Specs
The following tables list the screw size of terminal and recommended torque for tightening for 
each of the SJ300 inverter models (400V models are on the next page).
CAUTION: Fasten the screws with the specified fastening torque in the table below. Check for 
any loosening of screws. Otherwise, there is the danger of fire.
Note 1: The recommended ring lug connector listing consists of wire size – screw size 
format. The wire sizes are in AWG or mm
2
 format. For AWG wire sizes, bolt sizes 
for the ring lug centers are: #10, #12, 1/4”,  5/16”, and 1/2”. For metric wire sizes, 
bolt sizes for the ring lug centers are: 6 = 6M, 8 = 8M, 10 = 10M.
TIP: AWG = American Wire Gauge. Smaller numbers represent increasing wire thickness.
kcmil = 1,000 circular mils, a measure of wire cross-sectional area
mm
2
 = square millimeters, a measure of wire cross-sectional area
Input 
Voltage
Motor 
Output
200V
Inverter Models
Screw size 
of terminal
Ring lug connector *1
Torque
HP
kW
(AWG-bolt)
(mm
2
–bolt)
ft-lbs
(N-m)
200V
1/2
0.4
SJ300-004LFU
M4
20–#10
1.25–4
1.1
1.5
1
0.75
SJ300-007LFU
M4
20–#10
1.25–4
1.1
1.5
2
1.5
SJ300-015LFU
M4
14–#10
2–4
1.1
1.5
3
2.2
SJ300-022LFU
M4
14–#10
2–4
1.1
1.5
5
3.7
SJ300-037LFU
M4
10–#10
3.5–4
1.1
1.5
7.5
5.5
SJ300-055LFU
M5
8–#12
5.5–5
1.8
2.5
10
7.5
SJ300-075LFU
M5
8–#12
8–5
1.8
2.5
15
11
SJ300-110LFU
M6
4–1/4
14–6
3.6
4.9
20
15
SJ300-150LFU
M6
2–1/4
22–6
3.6
4.9
25
18.5
SJ300-185LFU
M6
4–1/4
14–6
3.6
4.9
30
22
SJ300-220LFU
M8
4–5/16
14–8
6.5
8.8
40
30
SJ300-300LFU
M8
2–5/16
22–8
6.5
8.8
50
37
SJ300-370LFU
M8
1–5/16
30–8
6.5
8.8
60
45
SJ300-450LFU
M10
1/0–1/2
38–10
10.1
13.7
75
55
SJ300-550LFU
M10
2/0–1/2
60–10
10.1
13.7