Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
SJ300 Inverter
Configur
ing Dr
iv
P
a
ra
met
e
rs
3–29
“B” Group: Fine-Tuning Functions
The “B” Group of functions and parameters adjust some of the more subtle but useful aspects 
of motor control and system configuration.
Automatic 
Restart Mode and 
Phase Loss
The restart mode determines how the inverter will resume operation after a fault causes a trip 
event. The four options provide advantages for various situations. Frequency matching allows 
the inverter to read the motor speed by virtue of its residual magnetic flux and restart the output 
at the corresponding frequency. The inverter can attempt a restart a certain number of times 
depending on the particular trip event:
• Over-current trip, restart up to 3 times
• Over-voltage trip, restart up to 3 times
• Under-voltage trip, restart up to 16 times
When the inverter reaches the maximum number of restarts (3 or 16), you must power-cycle the 
inverter to reset its operation.
Other parameters specify the allowable under-voltage level and the delay time before restarting. 
The proper settings depend on the typical fault conditions for your application, the necessity of 
restarting the process in unattended situations, and whether restarting is always safe.
Input 
power
Motor 
speed
Power failure
Inverter
output
Power failure > allowable power 
fail time (B002), inverter trips
Input 
power
Motor 
speed
Inverter
output
Power failure < allowable power fail 
time (B002), inverter resumes
Power failure
Retry wait time
Allowable
power fail time
Allowable
power fail time
free-running
free-running
B002
B003
B002
t
t
0
0
“B” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
B001
Selection of automatic 
restart mode
Select inverter restart 
method, four option codes:
00 Alarm output after trip,        
automatic restart 
disabled
01 Restart at 0Hz
02 Resume operation after 
frequency matching
03 Resume previous freq. 
after freq. matching, then 
decelerate to stop and 
display trip info
✘ ✔
00
00
00
>b001 IPS
POWER        ALM