The following table shows the available analog input settings. Parameter 
A005
 and the 
input terminal [AT] determine the External Frequency Command input terminals that are 
available, and how they function. The analog inputs [O] and [OI] use terminal [L] as the 
reference (signal return). 
A005 
[AT] Input 
Analog Input Configuration 
ON [OI] 
00 
OFF [O] 
ON 
Integrated POT on external panel
02 
OFF [O] 
ON 
Integrated POT on external panel
03 
OFF [OI] 
 