Chapter 2  Setup
29
P2X0-0202-01EN    ETERNUSmgr User Guide -Introduction-
All Rights Reserved, Copyright © FUJITSU LIMITED 2007
2
Caution: 
"_stxpoll.ini" is provided as a model file. If you copy this file to make a new setup file, be sure to
keep the original file as is.
2.5.3
Adding the Extra Target Devices to the Top Menu File
When monitoring multiple target devices, edit the Top Menu file as follows.
Note that if the target device is other than ETERNUS2000, each target address must have either 
"/login.htm" or "/login_jp.htm" added to the end.
The following example uses a configuration with two ETERNUS3000s and one ETERNUS2000 to show
how the top menu file should be edited to allow all three devices to be monitored. The top menu file should
be edited in the same way when monitoring other devices.
[Example]
• 1st Target Device (ETERNUS3000#1)
Target Address = http://000.000.000.001
Alarm History Files URL = domain-name/eternusmgr/ETERNUS3000_1
• 2nd Target Device (ETERNUS2000#1)
Target Address = http://000.000.000.002
Alarm History Files URL = domain-name/eternusmgr/ETERNUS2000_1
• 3rd Target Device (ETERNUS3000#2)
Target Address = http://000.000.000.003
Alarm History Files URL = domain-name/eternusmgr/ETERNUS3000_2
↓ Becomes
<HTML>
  
(omission)
<H2>Select RAID Device</H2>
<TABLE><TR><TD>
<OL>
<LI>
<a href="http://000.000.000.001:80/login.htm" target="_blank">ETERNUS3000
 #1</a>
</OL>
</TD></TR></TABLE>
<HR>
<H2>Show hardware error detect log list</H2>
<TABLE><TR><TD>
<OL>
<LI>
<a href="http://domain-name/eternusmgr/ETERNUS3000_1" target="_blank">
 ETERNUS3000 #1</a>
<!-- Status of 000.000.000.001 --><font color="red">(*Offline*)</font>
</OL>
</TD></TR></TABLE>
  
(omission)
</HTML>