6.4  Log Messages
ETERNUSmgr User Guide -Introduction-    P2X0-0202-01EN
Server Status Change (CODE 012)
[Explanation] There has been a change in the target device’s status.
[Response]
If the component that caused the problem is included in the message, login to the
target device and check the status of that component.
When "No hardware error detected." is displayed, there is no need to do anything.
Detection of the offline status is indicated when "No hardware report detected.
(Offline)" is displayed. In this case, check for problems with the target device, fail-
ures in the communications route, and errors in the setup file.
 Work files create to "temp directory" (CODE 014)
[Explanation] ETERNUSmgr has created a work file in the directory indicated in this message.
[Response]
None
Warning Messages for Parameter Settings (CODE 1XX)
Bad Parameter "parameter" (CODE 102)
[Explanation] This parameter setting is invalid.
[Response]
Correct the parameter setting.
Undefined Parameter "parameter" (CODE 103)
[Explanation] This parameter setting is not recognized.
[Response]
Correct the parameter setting.
Parameter too long "parameter" (CODE 104)
[Explanation] Too many characters are used in this parameter setting.
[Response]
Correct the parameter setting.
Not NULL Parameter "parameter" (CODE 105)
[Explanation] NULL is not allowed for this parameter setting.
[Response]
Set the parameter.
Directory Name too long "directory name" (CODE 106)
[Explanation] The directory name is too long.
[Response]
Set a shorter directory name.
Warning Messages (CODE 3XX)
Can't Connect Server "server:port" (CODE 301)
[Explanation] Failed to connect to the machine.
[Response]
Check the network environment (IP address, etc.).
Can't Send Mail "name@server" (CODE 304)
[Explanation] Failed to send an E-mail.
[Response]
Check the mail server is operating.