Install multimedia call handling (MMCH)
Issue 10 June 2005
319
 
Connect the endpoints
Use the following procedure and 
 to connect the endpoints:
Figure 100: Typical multimedia call handling connections
1. Each PC MMCH endpoint must contain a BRI adapter.
2. Connect a DCP telephone to a digital line circuit pack. The DCP telephone must be used in 
conjunction with the PC. Refer to the tables at the end of this chapter for the pinout of the 
digital line circuit pack.
3. Connect the PC BRI adapter to any BRI port on the Avaya Media Server. Refer to the tables 
at the end of this chapter for the pinout of an ISDN BRI circuit pack.
Administer the system
1. Call INADS and notify the representative that the Multimedia Call Handling (MMCH)? field 
on page 2 of the customer-options form must be changed to y.
2. Logoff the terminal and then log back on the terminal to see your changes.
Figure notes:
1. DCP telephone, 2 or 4 wire to 
match type of circuit pack
2. Personal computer
3. BRI adapter
4. D8W cord
5. 103A or modular wall jack
6. Main distribution frame
7. 25-pair cable to digital line circuit pack
8. 25-pair cable to BRI circuit pack or NT1, 
4-to-2 wire adapter
9. Avaya Media Server
10. Multimedia-interface circuit pack
11. Voice conditioner circuit pack