Installing the Switch in a Rack 
To install the switch in a rack, use the following procedure (and refer to Figure 3-1). To perform this 
procedure, you need the 19-inch rack-mount kit supplied with your switch. 
1.  Attach the supplied mounting brackets to the side of the switch.  
2.  Insert the screws provided in the rack-mount kit through each bracket and into the bracket mounting 
holes in the switch.  
3.  Tighten the screws with a #1 Phillips screwdriver to secure each bracket.  
4.  Align the mounting holes in the brackets with the holes in the rack, and insert two pan-head screws with 
nylon washers through each bracket and into the rack.  
5.  Tighten the screws with a #2 Phillips screwdriver to secure the switch in the rack. 
6.  If you want to install a GBIC module, proceed to “Step 3: Installing a GBIC Module,” next. Step 4: 
Checking the Installation.” 
 
Figure 3-1.  Attaching Mounting Brackets  
 
 
Step 3: Installing a GBIC Module 
The following procedure describes how to install a GBIC Gigabit Ethernet module, such as the NETGEAR 
AGM721F, in the switch’s Gigabit module bays. The AGM721F is sold separately from the 
GSM712/GSM712F.  If you do not want to install a GBIC module at this time, skip this procedure.   
 
To install a GBIC module: 
 
7.  Insert the GBIC module into the GBIC module bay.  Press firmly to ensure the module seats into the 
connector.