Siemens SCALANCE X-200 사용자 설명서

다운로드
페이지 296
Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
 
SCALANCE X-200 
240
 
Operating Instructions, 12/2011, A5E00349864-19 
Table 6- 37  Variables in the Interface directory 
Variable 
Access rights 
Description 
ifNumber 
Read only 
The number of different interfaces available in the component. 
Possible values: 4 - 8 
ifDescr 
Read only 
A description and possibly additional information for a port. Possible 
value: string with a maximum of 255 characters 
ifType 
Read only 
The value ethernet-csmacd(6) or optical(65) is entered for 
SCALANCE X-200. 
ifSpeed 
Read only 
Data transfer rate of the Ethernet port in bits per second. With 
SCALANCE X-200 devices, this is either 10 Mbps or 100 Mbps 
ifOperStatus 
Read only 
The current operating status of the Ethernet port. The following values 
are possible: ● up(1) ● down(2) 
ifLastChange 
Read only 
Length of time for which the selected port has been operating in the 
current status. The value is shown in hundredths of a second. 
ifInErrors 
Read only 
Number of received packages that were not forwarded to higher protocol 
layers because of an error. 
ifOutErrors 
Read only 
Number of packages that were not sent because of an error. 
Port Indexes 
The interface index must be used for port designations. The following table shows how the 
interface indexes are assigned to the ports. 
 
Interface Index 
Port 
Port 1 
Port 2 
Port 3 
Port 4 
Port 5 
Port 6 
Port 7 
Port 8 
24 
Port 24 
Important private MIB variables of an IE Switch X-200 
OID The private MIB variables of the IE Switch X-200 have the following object identifier:  
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1). 
ad(4196).adProductMibs(1).simaticNet(1).iScalanceX(5).iScalanceX200(2)